Article
This solution describes how to re-use the filters created by Event Source Management, in Active Views.
1. Log into Sentinel Control Center.
2. Click on Event Source Management and select Live View.
3. Right-click on the object that you want to use for filtering in Active Views and click on Open Active View.
4. ESM opens an Active View that shows only the events for the object you selected.
5. You can now detach this window and drag it outside of the ESM window, but it will close when you close ESM.
6. In order to re-use the filter that ESM created for this Window in ActiveViews, note the name of the object in the view:
7. Go back into the Sentinel Control Center and click on the create new ActiveView button.
![]()
8. Select the Z Axis event Attribute and click the Filter pull-down menu.
9. Find the filter with the same object name as the one you opened in ESM and click on Select (or double-click on it) to use it.
Disclaimer: As with everything else at Cool Solutions, this content is definitely not supported by Novell (so don't even think of calling Support if you try something and it blows up).
It was contributed by a community member and is published "as is." It seems to have worked for at least one person, and might work for you. But please be sure to test, test, test before you do anything drastic with it.
Related Articles
User Comments
- Be the first to comment! To leave a comment you need to Login or Register
- 6431 reads





0