Article
Problem
After I installed GroupWise 7.0.3, one of my users got the following error:
7111...failed (8503)
The error happened when the user was trying to remotely connect a 7.0.1 client to update 7.0.3 Groupwise agents. It was working perfectly before the update.
Solution
It turns out that the patch install wrote over my existing MTA startup. I had to re-enable Live Remote by putting the following switches back
in the MTA:
/LIVEREMOTE- /LRCONN-<# of connections to allow>
Now it works fine.
Disclaimer: As with everything else at Cool Solutions, this content is definitely not supported by Novell (so don't even think of calling Support if you try something and it blows up).