Hi All,
I was trying to Export an application object into an AOT file using APPXPORT Utility. I believe i used the syntax provided in the utility description but i cannot export it.

The syntax for the utility is,

APPXPORT treename objectname filepath

Now the object i need ed to export is MY-OBJECT and The Statement i used was,

APPXPORT.EXE MY-TREE MY-OBJECT.MY-APPS.Apps.MY-TREE C:\jana.aot
But i got the Error message "Exporting...Export error -601 (0xFFFFFDA7)"

Kindly guide me on how to specify the object name in the syntax( I guess i have a problem in specifing object name in the syntax ). I tried it different formats but no use.

Thanks in Advance

JanaGokul@gmail.com





User Comments

spond's picture

One idea

Submitted by spond on 2 October 2008 - 8:57pm.

The only thing I can see is that the parameter MY-OBJECT.MY-APPS.Apps.MY-TREE may not be correct, unless the top-level object (the "O") has the same name as the tree (not best practice).

The -601 error means that it cannot find the named object. If there is only one object that needs exporting, then the tools in ConsoleOne can be used (tools->ZENworks Utilities->Application Launcher Tools->Export Application object, then specify a name, and the AOT extension).

Shaun Pond

Export multiple objects

Submitted by JanaGokul on 3 October 2008 - 2:26am.

Thanks for your quick reply Shaun Pond !

I am trying to export multiple objects as a batch process. I mean to say i need to export my objects with out user inputs ( like ConsoleOne ).
I will try another/correct way for specifying the object name and let you know if there are any quires.

Export multiple objects

Submitted by Anonymous on 13 October 2008 - 7:52am.

Did you try a leading dot at MY-OBJECT.MY-APPS.Apps.MY-TREE?
As I remember my exporting of applications the syntax should be:
APPXPORT MY-TREE .MY-OBJECT.MY-APPS.Apps.MY-TREE C:\jana.aot

Karl-Heinz Hildebrandt

It worked !

Submitted by JanaGokul on 13 October 2008 - 10:44pm.

Hi Karl,
As you mentioned, i missed the leading dot in the object name that troubled me all the way.
Now it's working. Thanks a lot for you.

Janarthanan

I remember

Submitted by Ghuebner on 6 October 2008 - 12:17am.

Long time ago I use the tool.
I remember you need one ore more dlls from an old netware client. Maybe it also help to map sys:puplic as search volume.