Article
ZENworks Universal Image – from base image to deployment
This article describes our imaging method, from creating the base/universal image to adding driver images and machine specific changes, then creating imaging scripts that will figure out which piece of hardware the image is being restored to and apply the correct imaging files. While this is one way to do it, it is by no means the only way. This is what’s worked for us and I hope it will help someone else out there.
Step one: deployment design
We wanted the base image to be as lean as possible, and use scripting to add any drivers or applications required. Below is an overview of how it should work.
As we are a multi-site company we have to also take into account changes required for each site – these are things like Novell client properties, ZENworks server address, NTP servers and Symantec antivirus groups.
Step two: create the base image
PC type
During the initial XP Setup, press the F5 key when Setup asks you to press F6 for adding mass storage drivers. This is where you specify the HAL to be installed. I chose "Advanced Configuration and Power Interface (ACPI) PC".
HDD size
Handy Hint
Microsoft Best Practices for image deployment suggest that you should use the smallest possible partition size. This will keep the size of the image file reduced and will allow you to deploy the image to machines with smaller hard drives then the original.
Recommended Settings:
- Base Windows XP with SP3
Create a C:\ partition that is 4030MB in size - Base Windows XP with SP3 OS + Office
Create a C:\ partition that is 6030MB in size
Choose to use a 6030MB disk (because it gave me a little breathing room!)
Regional options
Change all regional/keyboard options to English (New Zealand). Remove English (US).
Personalize your Software
Name = a name
Organisation = Company name
Computer name and administrator password
Computer name = COMPANY-IMAGE
No admin password set
Date and Time
Timezone = GMT+12 (Auckland, Wellington)
Automatically adjust clock for daylight savings = ticked
Network settings
Typical settings
Left the default "Workgroup"
Pre-login screens
Turned off windows update
Did not register Windows
User account creation
At the end of the OS install, Windows will prompt you to create a user account for the computer. I created one called "DELETEME" to remind me to delete it before imaging. (see further down)
Post-OS install configuration
Configure login screen
When the installation of the OS has completed successfully and you've booted into Windows, open up the Windows Control Panel and select "User Accounts".
- Select "Change the way users log on or off"
- Uncheck "Use the Welcome screen"
- Uncheck "Use Fast User Switching"
- Click "Apply Options"
- Log off of the computer.
- Login as Administrator
Remove un-needed programs
Start > Control Panel
- Add or Remove Programs
- Add/Remove Windows Components
- Accessories & Utilities > Games
- MSN Explorer
- Network Services
- Windows Messenger
Run Windows Update
Browse to http://update.microsoft.com and fully update, including a "Custom" update and update these components:
Component
.NET framwork 3.5 SP1
Group Policy preference client side extensions for Windows XP
Root Certificate update
Windows Media Player 11
Microsoft .NET framework 1.1
Configure desktop
| Browser | |||
| Home page | http://home.niwa.co.nz | ||
| Proxy settings | server | proxy.address.co.nz:80 | |
| By-pass proxy server for local addresses | TICKED | ||
| Advanced | Use the same proxy for all protocols | proxy.address.co.nz:80 | |
| Exceptions | Any exceptions | ||
| Windows Explorer settings | |||
| View | Status bar | ||
| View | Details | ||
| Tools | Folder Options | General tab | Use windows classic folders |
| Open each folder in the same window | |||
| Double-click to open an item (single click to select) | |||
| View tab | Defaults, except: | ||
| Untick 'Display simple folder view in Explorer's folder list | |||
| Show hidden files and folders | |||
| Display the full path in the title bar | |||
| Untick 'Hide extensions for known file types' | |||
| Untick 'use simple file sharing | |||
| Taskbar and start menu Properties | |||
| Taskbar tab | Untick | Lock the taskbar | |
| Autohide the taskbar | |||
| Hide inactive icons | |||
| Tick | Keep the taskbar on top of other windows | ||
| Group similar | |||
| taskbar icons | |||
| Show quick launch | Show the clock | ||
| Start menu | Customize | General tab | Large icons |
| Number of programs on start menu = 10 | |||
| Show IE on start menu, not Email client | |||
| Advanced tab | Tick open submenus when I pause over them with my mouse | ||
| Untick highlight newly installed programs | |||
| List my most recently opened documents | |||
| Start menu items | |||
| Control panel as a link Enable drag and dropping Favourites menu Help and support My computer as a link Don't display My Documents Don't display My Music My Network Places Don't display My Pictures Don't display Network Connections Printers and faxes Run command Search Untick Set Program access and defaults Don't display System Administrative Tools |
|||
- Moved Windows Explorer shortcut from Start > All Programs > Accessories to Start > All Programs
- Moved Command Prompt shortcut from Start > All Programs > Accessories to Start > All Programs
- Deleted Windows Movie Maker from Start > All Programs
- Deleted Remote Assistance from Start > All Programs
- Deleted Set Program Access and Defaults from Start > All Programs
- Deleted Remote Assistance from Start > All Programs
- Deleted Windows Catalog from Start > All Programs
- Deleted Windows Update from Start > All Programs
- Removed File and Settings Transfer Wizard from the Start Menu
- Removed Tour Windows XP from the Start Menu
| Quicklaunch icons | |||
| Internet Explorer Show desktop Windows Explorer |
|||
| Desktop Properties | |||
| (ie right-click desktop -> Properties) | |||
| Themes | Theme | Windows classic | |
| Desktop | Background | none | |
| Customise desktop | General Desktop icons | My Computer, My Network Places, Internet Explorer | |
| Untick Run desktop cleanup wizard every 60 days | |||
| Screen saver | Windows XP screensaver | ||
| Wait 10min, tick on resume password protect | |||
Note: monitor power see power options section below
| Control Panel | |||
| Power options | (ie Control Panel -> Power Options) | ||
| Turn off monitor 30 min | |||
| Turn off harddisks 45min | |||
Power scheme saved as "Company Standard"
| Security Center | |||
| Change the way security center notifies me | Untick all options | ||
| Windows Firewall | |||
| Turn off | |||
| System | |||
| Advanced tab | Performance Settings | Adjust for best performance | |
| Virtual memory | Change | Custom size: 2048min, 2048max | |
| Regional and language options | |||
| Standards and formats: English | |||
| (New Zealand) | |||
| Location | New Zealand | ||
| Advanced tab | Language for non-unicode programs | English (New Zealand) | |
Configure IE search box
Run IE7 (first time after updates above). Chose to change the default search provider and change to Google.
Command prompt
Start > All Programs > Command prompt
- Menu > Defaults > Tick Quick Edit Mode
Windows Explorer
- Right-click the Windows explorer icon on the quicklaunch bar
- Properties
- Shortcut tab
- In the 'target' paste the below in%SystemRoot%\explorer.exe /e
Repeate for the icon in Start > All Programs
Windows Media Player
Run Windows Media Player, accept all defaults and finish wizard.
Hide My Documents folder between users
Set My Documents to private
Windows Registry Editor Version 5.00
[HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Explorer\MyComputer\NameSpace\DelegateFolders\{59031a47-3f72-44a7-89c5-5595fe6b30ee}]
@=""
Configure NTP server
Start > Control Panel
Internet Time tab
Tick "Automatically synchronize with an Internet Time server"
Server = ntp1.server.co.nz
Remove hotfix backups
From \\niwa-bacon\archive\itsupp\setup\winxp\Remove hotfix uninstall information\
copied to niwa-image and ran xp_remove_hotfix_backup.exe
Removed all backup information
Recycle bin
Right-click > Empty
Copy the Administrator profile to Default User
Reboot the computer
Logon to the computer with the username "Deleteme" which was created as part of the Windows setup.
Open "My Computer"
- Choose "Tools"
- Choose "Folder Options"
- Choose the tab "View"
- Put a check in the box "Show hidden files and folders"
- Click "Apply to All Folders"
- Click OK
- Close "My Computer"
Click on the Windows Start Menu
- Right-Click on "My Computer"
- Chose Properties
- Choose the tab "Advanced"
- Under the User Profiles section choose "Settings"
- Single-click on the Administrator's profile and choose "Copy To"
- Select Browse, and browse to the folder:
"C:\Documents and Settings\default user" - Under the "Permitted to use option click "Change"
- Type in "Everyone"
- Click OK
- Click OK to copy the profile
- When this has completed reboot and login to the computer with the username "Administrator"
We will now delete the user profile for "DeleteMe" as follows
- Right-click on "My Computer"
- Choose "Manage"
- Expand "Local Users and Groups"
- Delete the username "DeleteMe"
- Close the MMC
- Open Windows Explorer
- Delete the folder "C:\Documents and Settings\DeleteMe" which is the default user profile that was created.
- Empty the Windows Recycle Bin
Sysprep
Pre-sysprep image
At this point create a pre-sysprep image called basexpB4sp.zmg
Boot from CD (download latest imaging drivers/CD from http://download.novell.com)
- img
- File > Make image > Server
- Server = IPaddressofserver
- Filename = //IPaddressofserver/path/basexpb4sp.zmg
Configure sysprep
- From the Windows XP Sp3 CD, extract the Deploy.cab file located in the Support\Tools folder to C:\sysprep
- Download, extract and copy mysysprep to C:\sysprep
- Copy and edit the sysprep.inf, from previous images (there are far too many sysprep options to list here, see the sysprep section later on for some explanation of what we do)
mp.inf, up.inf are exactly the same except for this line:
up.inf
UpdateHAL=ACPIAPIC_UP,%WINDIR%\inf\hal.inf
mp.inf
UpdateHAL=ACPIAPIC_MP,%WINDIR%\inf\hal.inf
inside mysysprep.inf I have these lines:
GenuineIntel.MP=mp.inf
GenuineIntel.UP=up.inf
AuthenticAMD.MP=mp.inf
AuthenticAMD.UP=up.inf
which mean when mysysprep starts on first boot it detects which type of processor is running and assigns the correct .inf file, which in turn installs the correct hal.
The sysprep.inf already has the masstoragedevices section built, but if you want to rebuild it, in sysprep.inf add these lines to the bottom of the file.
[sysprep] BuildMassStorageSection=Yes
Then from a command prompt run:
C:\sysprep\sysprep.exe -BMSD
However remember that I have added some new Intel mass storage devices drivers manually - these are located here in the image:
c:\sysprep\drivers\mass
and in sysprep.inf
[SysprepMassStorage] .. .. PCI\VEN_8086&DEV_2681&CC_0106="C:\sysprep\Drivers\mass\iaAHCI.inf" PCI\VEN_8086&DEV_27C1&CC_0106="C:\sysprep\Drivers\mass\iaAHCI.inf" PCI\VEN_8086&DEV_27C5&CC_0106="C:\sysprep\Drivers\mass\iaAHCI.inf" PCI\VEN_8086&DEV_2821&CC_0106="C:\sysprep\Drivers\mass\iaAHCI.inf" PCI\VEN_8086&DEV_2829&CC_0106="C:\sysprep\Drivers\mass\iaAHCI.inf" PCI\VEN_8086&DEV_2922&CC_0106="C:\sysprep\Drivers\mass\iaAHCI.inf" PCI\VEN_8086&DEV_2929&CC_0106="C:\sysprep\Drivers\mass\iaAHCI.inf" PCI\VEN_8086&DEV_3A02&CC_0106="C:\sysprep\Drivers\mass\iaAHCI.inf" PCI\VEN_8086&DEV_3A22&CC_0106="C:\sysprep\Drivers\mass\iaAHCI.inf" PCI\VEN_8086&DEV_2682&CC_0104="C:\sysprep\Drivers\mass\iaStor.inf" PCI\VEN_8086&DEV_27C3&CC_0104="C:\sysprep\Drivers\mass\iaStor.inf" PCI\VEN_8086&DEV_27C6&CC_0104="C:\sysprep\Drivers\mass\iaStor.inf" PCI\VEN_8086&DEV_2822&CC_0104="C:\sysprep\Drivers\mass\iaStor.inf" PCI\VEN_8086&DEV_282A&CC_0104="C:\sysprep\Drivers\mass\iaStor.inf"
Remove drivers
Start > Control Panel > System > Hardware tab > Device Manager.
Uninstall the below, select no to any reboot requests.
- Disk drives
- DVD/CD-ROM drives
- Floppy disk controllers
- IDE ATA/ATAPI controllers
- Monitors
- Network adapters
- Ports (COM & LPT)
- Processors
- ALL "unknown" devices
Run sysprep
I then ran mysysprep.exe and chose:
- Use mini-setup
- Detect non-plug and play hardware
- Shutdown PCReseal
Post-sysprep image
Created a post-sysprep image called base.zmg
Booted from CD (downloaded latest imaging drivers/CD from http://download.novell.com)
- img
- File > Make image > Server
- Server = IPaddressofserver
- Filename = //IPaddressofserver/path/base.zmg
Step three: drivers.zmg and monitor.zmg
We created a folder ‘drivers’ below the root of our imaging directory to hold all our driver images. Each .zmg file populates the directories below:
\Sysprep\Drivers\ \audio \chipset \intelinf \misc1 \misc2 \misc3 \misc4 \modem \monitor \mouse \nic1 \nic2 \nic3 \scsi \video
specific to each model of machine, which is found during imaging. See further down for how.
drivers/monitor.zmg Adds ALL drivers for monitors we have to \sysprep\drivers\monitor, that way sysprep can decide which driver to install.
Step four: applications.zmg
This adds (to C:\temp) the below applications.
- Novell Client v4.91SP4
- ZENworks agent v7sp1hp6
- Symantec Antivirus 10.1.6
These are installed via a runonce.bat file that runs the first time the machine boots after the image is put down. Runonce.bat also calls machine_specific.bat (see step 6). Here’s what the runonce.bat looks like:
REM install Novell Client start "novell" /wait "%systemdrive%\Temp\491sp4\acu.exe" /U REM install ZENworks 7 agent start "zenworks" /wait "%windir%\system32\msiexec.exe" /i "%systemdrive%\ZfDAgent.msi" /qb ADDLOCAL=ALL LOGIN_PASSIVE_MODE=0 STARTUP_APPEXPLORER=1 ZENWORKS_TREE=TREENAME REBOOT=ReallySuppress REM install Symantec Antivirus (GRC.DAT populated from site\<site>.zmg) start "sav" /wait "%windir%\system32\msiexec.exe" /i "%systemdrive%\Temp\sav\Symantec AntiVirus.msi" /qb REBOOT=ReallySuppress REM import novell client properties (file updated by site\<site>.zmg) reg import "%systemdrive%\Temp\novell_client_properties.reg" REM import zenworks middle-tier server address (file updated by site\<site>.zmg) reg import "%systemdrive%\Temp\zenworks.reg" REM import time server settings (file updated by site\<site>.zmg) reg import "%systemdrive%\Temp\time.reg" REM any machine-specific installs to do? CALL "%systemdrive%\machine_specific.bat" REM Clean-up rmdir /S /Q "%systemdrive%\Temp\491sp4" rmdir /S /Q "%systemdrive%\Temp\sav" del /Q "%systemdrive%\ZfDAgent.msi" del /Q "%systemdrive%\Temp\novell_client_properties.reg" del /Q "%systemdrive%\Temp\zenworks.reg" del /Q "%systemdrive%\Temp\time.reg" REM reboot the system "%windir%\system32\shutdown.exe" -r -t 05 -fREM reboot the system "%windir%\system32\shutdown.exe" -r -t 05 –f
The registry files that are imported in the above batch file are put in place in the next step.
Step five: site specific changes
site/<site>.zmg
Used to edit settings/files on a per-site basis:
- Symantec GRC.dat -
copy the correct GRC.dat file into C:\temp\SAV\ so that SAV imports into the right group - novell_client_properties.reg
This is imported during the runonce.bat (added in the 'applications.zmg' above) and configures the Novell client for the specific site of that machine. - zenworks.reg
add a registry key to set the local ZENworks server - time.reg
add a registry key to set the local time server(s) up
Step six: machine-specific/<model>.zmg
This adds files/installs specific to each model of machine (if required). This applies to notebooks usually. The .zmg also adds a machine_specific.bat to %systemroot%, which then gets called during runonce.bat on first boot. An example .zmg for one of our HP Compaq 6930p laptops puts these folders on the PC:
Temp\ati_video
Temp\hp_bluetooth
Temp\quicklaunch
And the machine_specific.bat looks like this:
REM ATI Catalyst Control Center start "dotnet" /wait "%systemdrive%\Temp\ati_video\NET32\dotnetfx.exe" /q:a /c:"install.exe /q" start "ati" /wait "%systemdrive%\Temp\ati_video\CCC\setup.exe" /S /V"/qb REBOOT=ReallySuppress" REM HP Integrated module (Bluetooth stack) start "bt" /wait "%windir%\system32\msiexec.exe" /i "%systemdrive%\Temp\hp_bluetooth\Win32\BTW.msi" TRANSFORMS="%systemdrive%\Temp\hp_bluetooth\Win32\1033.mst" ALLUSERS=2 /qn REM HP Quicklaunch buttons start "hpqlb" /wait "%systemdrive%\Temp\quicklaunch\setup.exe" /s /f1"%systemdrive%\Temp\quicklaunch\setup.iss" REM cleanup rmdir /S /Q "%systemdrive%\temp\ati_video" rmdir /S /Q "%systemdrive%\temp\hp_bluetooth" rmdir /S /Q "%systemdrive%\temp\quicklaunch"
Step seven: sysprep.inf and "mysysprep"
Sysprep
Sysprep, or System Preparation Utility can be used to prepare an operating system for disk cloning and restoration via a disk image. It can be extracted from the WinXP CD under Support/Tools/deploy.cab.
Once extracted I ran setupmgr.exe and created a fully automated install (see below "mysysprep" for more information about this).
Mysysprep
HAL selection
Sysprep cannot intelligently select the right hardware abstraction layer (HAL) during first boot (after imaging), mysysprep can do just that. Mysysprep detects which type of processor is installed (Intel, AMD, single-core, multi-core) and applies the correct HAL.
i.e. in mysysprep.inf are these lines:
GenuineIntel.MP=mp.inf
GenuineIntel.UP=up.inf
AuthenticAMD.MP=mp.inf
AuthenticAMD.UP=up.inf
If the vendor ID is GenuineIntel and the logical processor count is greater than 1, The answer file mp.inf will be merged to Sysprep.inf. If the logical processor count is 1, the answer file up.inf will be merged.
Intel processors have the vendor ID: GenuineIntel, while AMD processors have AuthenticAMD
up.inf and mp.inf are exactly the same, except for this line
up.inf
UpdateHAL=ACPIAPIC_UP,%WINDIR%\inf\hal.inf
mp.inf
UpdateHAL=ACPIAPIC_MP,%WINDIR%\inf\hal.inf
PC naming
Mysysprep also allows us to name the PC from the BIOS asset tag information. By adding the below to to the sysprep.inf (as well as up.inf and mp.inf) we can have a fully automated install of WinXP that also names the PC as per standard naming conventions.
[UserData]
ComputerName="%AssetTag%"
Step eight: Editing the initrd and PXE menu
Editing the PXE menu
go here: \\servername\sys\tftp
Run MEDITOR.exe
Open your menu – if you’ve never edited it it’ll be DEFMENU.MNU
Add a new item “Restore WinXP image”
Put any heading, information and help screens you want
In the command box put:
loadlin.dnx cmds\z_xpimage.cmd
Save the file
Now go to \\servername\sys\tftp\cmds
Here’s what our z_xpimage.cmd looks like:
KERNEL boot/linux APPEND initrd=boot/initrd vga=0x314 install=tftp://$TFTPIP/boot rootimage=/root PROXYADDR=IP_ADDRESS_OF_SERVER TFTPIP=$TFTPIP splash=silent PXEBOOT=YES mode=2 IMGCMD="runScript.s /bin/xp_image.s"
Editing initrd
copy \\servername\sys\tfp\boot to a temporary directory on a linux machine
mkdir /home/baarsd/boot cd /home/baarsd/boot
Extract initrd...
mv initrd initrd.gz
gunzip initrd.gz
mkdir work
cd work
cpio -idmuv < ../initrd >/dev/null 2>&1
Now we have initrd extracted to /home/baarsd/boot/work.
From here we can e.g. add script files to /bin - make sure you make the rights the same as the other files in that directory.
chmod 755 xp_image.s
Note: xp_image.s is explained below
Re-create the initrd cd /home/baarsd/boot/work find . | cpio --quiet -o -H newc > ../initrd cd .. gzip -v9c initrd > initrd.gz mv initrd.gz initrd
You can then copy the file back to your Zenworks server.
Step nine: imaging script
Site selection
Initially we need to detect where the PC is and what ZENworks server to use - e.g.
# Wellington if [ $PROXYADDR = "192.168.10.1" ] then site_path="//$PROXYADDR/arena/zenimages/ " fi
This sets the site_path variable so the script knows where to look for images.
Base image
With the site found, we can restore the base image.
# Clear the image safe data zisedit -c # install the image img rp $PROXYADDR $site_path/base.zmg
Which also clears the image safe data prior to imaging.
Drivers and machine-specific software
From the imaging command prompt you can do this:
hwinfo --bios
Which gives you information from and about the BIOS of the PC you run it on...so expanding on that:
hwinfo --bios | grep 'Product:'
gives us 3 results (on the dc7800 I tried it on anyway) ... one of which is the model name of the PC
hwinfo --bios | grep 'Product:' gives Product: "HP Compaq dc7800 Small Form Factor" Product: "0AA8h"
so....in a script we can do this
if [ `hwinfo --bios | grep -ic 'Product: "HP Compaq dc7800 Small Form Factor"' = "1"` ] img rp $PROXYADDR drivers/dc7800.zmg fi
So with that information we can restore the base.zmg (initial image) then put the drivers specific to that hardware on the PC.
Using the same hardware detection we can expand that to include the restore of the machine-specific software - e.g.
# # HP 550 # if [ 'hwinfo --bios | grep -ic "HP 550"' = "1" ] then img rp $PROXYADDR $site_path/drivers/550.zmg img rp $PROXYADDR $site_path/machine-specific/550.zmg fi
Monitor drivers
img rp $PROXYADDR $site_path/drivers/monitor.zmg
Application images
# add applications to run post-image (ie during first login) img rp $PROXYADDR $site_path/applications.zmg
Site specific changes
# site specific changes required # Auckland if [ $PROXYADDR = "192.168.12.3" ] then img rp $PROXYADDR $site_path/site/auckland.zmg fi
The above script then obviously gets put in the initrd as explained in step 8.
References
- What Is the Preboot Execution Environment (PXE)?
- Modifying ZENworks Imaging Resource Files
- Hardware detection - Novell forums
- Windows XP SP3 is Out - Time to Rebuild Those Base Images!
- How To Create a Universal Ghost Image Using Sysprep and Mysysprep
- mysysprep
Disclaimer: As with everything else at Cool Solutions, this content is definitely not supported by Novell (so don't even think of calling Support if you try something and it blows up).
It was contributed by a community member and is published "as is." It seems to have worked for at least one person, and might work for you. But please be sure to test, test, test before you do anything drastic with it.
Related Articles
User Comments
Step Three :S
Submitted by AdamBock on 14 April 2009 - 11:01pm.
I am a little stuck on Step Three...
How do you create driver .zmg files?
Cheers,
- Be the first to comment! To leave a comment you need to Login or Register
driver.zmg
Submitted by baarsd on 15 April 2009 - 2:53pm.
Hi Adam,
to create the driver.zmg files -
Launch ConsoleOne
Tools > Zenworks Utilities > Imaging > Image Explorer
(this assumes you have the zenworks snapins for ConsoleOne installed)
Then in Image Explorer
Select Partition 1
Image > Create Directory - "Sysprep"
Image > Create Directory - "Drivers"
Then the driver folders - I have 15 folders, listed below:
audio
chipset
intelinf
misc1
misc2
misc3
misc4
modem
monitor
mouse
nic1
nic2
nic3
scsi
video
then for each model (d510, dc7600, dc7700...etc) I populate those folders with the drivers for them - then I save the new image as the model name - dc7600.zmg, d510.zmg ...etc
Might may to create a drivers_example.zmg with the folder structure above so you can just load that zmg, put files in and then save as a new filename (dc7700.zmg or something)
Hope that helps!
- Be the first to comment! To leave a comment you need to Login or Register
driver.zmg
Submitted by AdamBock on 15 April 2009 - 5:43pm.
Thanks heaps baarsd!
That seems really simple however I am having problems with Image Explorer.
I have tried installing novell-zenworks-zmgexplorer-10.1.2.0.msi on my workstation to follow the steps provided but it does nothing?
When I ran the msi, it did nothing so I extracted the files from the msi and tried to run them and still no luck. The batch files were throwing me errors and the .jar files were doing nothing.
I have the latest version of Java installed and I have tried with older versions also. I have a feeling the batch files may not be working as they point to server directories however I know that it's possible to use this tool on workstations.
You may notice that my version of image explorer is 10.1.2 - perhaps there is a bug in it? Do you know of any work arounds or are you able to send me an older version of image explorer?
My email address is abock@immanuel.sa.edu.au (you might want to change the extension of the file to .randomextension as our schools mail filter is pretty fussy.
Thanks for your time and help, it is much appreciated.
Cheers,
Adam
- Be the first to comment! To leave a comment you need to Login or Register
- Be the first to comment! To leave a comment you need to Login or Register
I need to correct sth.
Submitted by aspirer on 20 February 2010 - 11:00pm.
in copy profile section,
I believe the article both here and the reference have sth. wrong.
we should copy "Deleteme" profile to "Default Users", because we config a lot when login with this account.
So, should copy this profile to default users's profile, but not administrator's.
comment by aspirer
- Be the first to comment! To leave a comment you need to Login or Register
Hi aspirer, that is incorrect
Submitted by baarsd on 18 July 2010 - 5:17pm.
Hi aspirer,
that is incorrect - if you don't copy the administrator profile into the default user profile then when you image the machine you don't get the correct profile settings that you want to use. That's been my experience anyway!
Thanks,
Dylan
- Be the first to comment! To leave a comment you need to Login or Register
Avoiding modifying the initrd file when the script changes.
Submitted by stevenguard on 9 September 2010 - 6:07am.
Dear all,
What a great article.
I made a slight alteration to this . I write the following get_file.s script into the initrd.
This file then tftp's the script file i want to run from the zen works server. I can then modify the script file for new hardware and not have to worry about modifying the initrd again.
get_file.s script file in initrd
********
# connect to proxy server and get script file
setterm -clear
NC='\e[0m'
RED='\e[0;31m'
WHITE='\e[1;37m'
YELLOW='\e[1;33m'
echo
echo -e "$WHITE Transferring script file from Zen Server - ${NC}" $PROXYADDR
echo
sleep 3
cd /bin
#connect to Zen server and get command script
tftp $PROXYADDR -m binary -c get xp_bri.s
#mod rights to script file
chmod 755 xp_bri.s
# run file
echo "File transferred. Loading...."
sleep 1
xp_bri.s
*****************
Currently modifing the xp_bri.s (our version of xp_image.s) to read a text file containing the hardware search text and corresponding image file to lead. This should allow the support chaps to add new hardware to text file without having to edit the script every time.
Steve.
- Be the first to comment! To leave a comment you need to Login or Register
xp_bri.s as promised
Submitted by stevenguard on 22 December 2010 - 10:06am.
# File to automatically select image and load it
# v4 - update to non-detection routine to ask for an image name if known
NC='\e[0m'
RED='\e[0;31m'
WHITE='\e[1;37m'
YELLOW='\e[1;33m'
bldstdver="Build46.zmg"
bldtabver="TabletBuild46.zmg"
echo
echo -e "$WHITE ****** Automated Image Selection ****** ${NC}\n"
echo
echo "Loading list of valid PC's and images"
pcfile=pclist.txt
tftp $PROXYADDR -c get $pcfile
pccount=0
index=0
while read line ; do
PCARRAY[$index]="$line"
index=$(($index+1))
done < $pcfile
let pccount=($index/2)
# echo "PCARRAY is: ${PCARRAY[*]}"
echo
echo "Total PC's in the file: ${pccount}"
sleep 1
# dimension elements with contents of pcarray
elements=${#PCARRAY[@]}
# loop
#echo "Total elements in array ${elements}"
# show platforms and build
echo ; echo
echo -e "$WHITE Valid Platform and Build List ${NC}\n"
for ((p=0;p<$elements;(p=$p+2)));do
let b=($p+1)
# echo " Platform: ${PCARRAY[${p}]} Build : ${PCARRAY[${b}]}"
printf " Platform: ${PCARRAY[${p}]} \t \t Build: ${PCARRAY[${b}]} \n"
done
# BRI
if [ $PROXYADDR = "128.127.150.7" ]
then
live_site_path="//bhts-zen7/images/current"
beta_site_path="//bhts-zen7/images/beta"
fi
# Set Path to live
image_path=$live_site_path
# Setup detection
detected=0
platform=0
#echo "Detected="$detected
# Determine Hardware Platform
echo
echo -e "$YELLOW Looking for Hardware. Please wait... ${NC}\n"
echo
let b=0
for ((p=0;p<$elements;(p++)));do
let b=($p+1)
for platform in $(hwinfo --bios | fgrep -ic "${PCARRAY[${p}]}"); do if [ $platform -eq 1 ] ; then build="${PCARRAY[${b}]}" ; echo " Detected ${PCARRAY[${p}]}" ; detected=1 ; fi ; done
done
# echo " Build Image is "$build
case $detected in
0) echo -e "$RED Hardware not found. Hardware information is. ${NC}\n" ; echo -e $(hwinfo --bios | fgrep -i "Product") "\n";;
1) echo " Build Image is "$build ;echo -e "\n Clearing the local Zisdata \n" ; zisedit -c ; echo -e "\n $WHITE Selected Image ${NC}"$image_path/$build ;
echo ; echo -e "$WHITE Loading Zen Imaging Engine .... ${NC}\n" ; sleep 2 ; img restorep $PROXYADDR $image_path/$build ; exit ;;
esac
# load image
#echo
#echo
#echo -e "$WHITE Selected Image ${NC}"$image_path/$build
#echo
#echo -e "$WHITE Loading Zen Imaging Engine .... ${NC}\n"
#sleep 3
#img restorep $PROXYADDR $image_path/$build
# end
if [ $detected -eq 0 ] ; then
echo "Do you want to load an image file anyway ?."
read
case $REPLY in
y) echo "If you know the image name you require please enter it now, including the .zmg extension." ; read image ;;
n) echo -e "\n Exiting ...." ; exit ;;
esac
fi
# Clear the image safe data
echo -e "$WHITE Clearing the local Zisdata ${NC}\n"
zisedit -c
echo -e "\n Live of Beta image ?."
read
case $REPLY in
l) img restorep $PROXYADDR $live_site_path/$image ;;
b) img restorep $PROXYADDR $beta_site_path/$image ;;
esac
exit
- Be the first to comment! To leave a comment you need to Login or Register