Search
Search results
- Rollback SLES Online Updates with Software RAID1
-
... to use a redundant array of independent disks ( RAID ). You should be able to use hardware or software RAID to accomplish the rollback, but the technique is dependent on how the RAID ...
Article - jrecord - 11 Apr 2008 - 10:33am - 0 comments - 0 attachments - 3 groups
- Installing SLES on Software RAID1
-
... Using a redundant array of independent disks ( RAID ) is one way to build redundancy. A redundancy strategy is not a backup ... implemented backup strategy. I personally believe the best RAID solution is hardware RAID. However, when budgets are constrained, software ...
Article - jrecord - 7 Apr 2008 - 7:09am - 13 comments - 0 attachments - 3 groups
- GroupWise Clustering Basics: Part 2
-
... redundant Host Bus Adapters (HBAs), and at least RAID Level 1 hardware mirroring on the node's on-board disk subsystem ... SAN vendor can assist in proper design. Why do I need RAID Level 1 hardware mirroring for my cluster nodes? The answer is simple. ...
Article - GreggHinchman - 29 Feb 2008 - 7:03am - 0 comments - 0 attachments - 3 groups
- GroupWise Clustering Basics: Part 3
-
... to be running on the LUN's? Second, what level of RAID do you need? How many "hot spare" drives do you need? GroupWise, as ... a SAN Vendor's LUN Configuration Software What about RAID Level? In a SAN, you can have many different types of RAID level. Each ...
Article - GreggHinchman - 29 Feb 2008 - 6:57am - 0 comments - 0 attachments - 3 groups
- Ultimate Linux Desktop
-
... not make the partitioning too complex. LVM or software RAID may not be possible with this setup. I used common UNIX ...
Article - variia - 14 Feb 2008 - 4:16pm - 0 comments - 0 attachments - 3 groups
- GroupWise Dependency on eDirectory
-
... strings that haven't been cleaned up. If I said 8TB _RAID_ device, If I said 8TB _ RAID _ device, does that make more sense? As for the NSS code, I believe a ...
Blog Entry - dlythgoe - 6 Feb 2008 - 5:03pm - 53 comments - 0 attachments - 0 groups
- Solving a -614 Error in User App
-
... the 2.02 version time frame that we need a RAIIS (like RAID , but Redundant Array of Independent iManager Servers). I once ...
Article - geoffc - 6 Feb 2008 - 8:58am - 0 comments - 1 attachment - 1 group
- Same Server Data Migration - NetWare to OES 2 Linux
-
... If both SYS and VOL1 are partitioned on the same RAID then SLES/OES2 will show the entire NSS partition, both SYS and VOL1, ...
Article - mfaris01 - 5 Feb 2008 - 12:15pm - 4 comments - 0 attachments - 2 groups
- Using FreeNAS as a NetWare iSCSI Target. AKA: Cheap Mass Storage
-
... FreeNAS provides a (fairly) reliable software RAID FreeNAS can be loaded/run from USB drives/CDROM. A number of ... FreeNAS provides a (fairly) reliable software RAID FreeNAS can be loaded/run from USB drives/CDROM. A number of other ...
Article - sowenatedzonedotnet - 1 Feb 2008 - 7:32pm - 0 comments - 0 attachments - 2 groups
- Shared SCSI Two-Node Cluster
-
... hardware solution that can do shared SCSI with RAID . It happens that I have done this with very specific hardware, which ... SCSI hard drives. Dell also sells an appropriate RAID controller, the PERC 4DC or 4eDC controller line (The e stands for PCI ...
Article - geoffc - 12 Jan 2008 - 2:02am - 0 comments - 0 attachments - 2 groups
