Rollback SLES Online Updates with Software RAID1

... to use a redundant array of independent disks ( RAID ). You should be able to use hardware or software RAID to accomplish the rollback, but the technique is dependent on how the RAID ...

Article - jrecord - 11 Apr 2008 - 10:33am - 0 comments - 0 attachments - 3 groups

Installing SLES on Software RAID1

... Using a redundant array of independent disks ( RAID ) is one way to build redundancy. A redundancy strategy is not a backup ... implemented backup strategy. I personally believe the best RAID solution is hardware RAID. However, when budgets are constrained, software ...

Article - jrecord - 7 Apr 2008 - 7:09am - 13 comments - 0 attachments - 3 groups

GroupWise Clustering Basics: Part 2

... redundant Host Bus Adapters (HBAs), and at least RAID Level 1 hardware mirroring on the node's on-board disk subsystem ... SAN vendor can assist in proper design. Why do I need RAID Level 1 hardware mirroring for my cluster nodes? The answer is simple. ...

Article - GreggHinchman - 29 Feb 2008 - 7:03am - 0 comments - 0 attachments - 3 groups

GroupWise Clustering Basics: Part 3

... to be running on the LUN's? Second, what level of RAID do you need? How many "hot spare" drives do you need? GroupWise, as ... a SAN Vendor's LUN Configuration Software What about RAID Level? In a SAN, you can have many different types of RAID level. Each ...

Article - GreggHinchman - 29 Feb 2008 - 6:57am - 0 comments - 0 attachments - 3 groups

Ultimate Linux Desktop

... not make the partitioning too complex. LVM or software RAID may not be possible with this setup. I used common UNIX ...

Article - variia - 14 Feb 2008 - 4:16pm - 0 comments - 0 attachments - 3 groups

GroupWise Dependency on eDirectory

... strings that haven't been cleaned up. If I said 8TB _RAID_ device, If I said 8TB _ RAID _ device, does that make more sense? As for the NSS code, I believe a ...

Blog Entry - dlythgoe - 6 Feb 2008 - 5:03pm - 53 comments - 0 attachments - 0 groups

Solving a -614 Error in User App

... the 2.02 version time frame that we need a RAIIS (like RAID , but Redundant Array of Independent iManager Servers). I once ...

Article - geoffc - 6 Feb 2008 - 8:58am - 0 comments - 1 attachment - 1 group

Same Server Data Migration - NetWare to OES 2 Linux

... If both SYS and VOL1 are partitioned on the same RAID then SLES/OES2 will show the entire NSS partition, both SYS and VOL1, ...

Article - mfaris01 - 5 Feb 2008 - 12:15pm - 4 comments - 0 attachments - 2 groups

Using FreeNAS as a NetWare iSCSI Target. AKA: Cheap Mass Storage

... FreeNAS provides a (fairly) reliable software RAID FreeNAS can be loaded/run from USB drives/CDROM. A number of ... FreeNAS provides a (fairly) reliable software RAID FreeNAS can be loaded/run from USB drives/CDROM. A number of other ...

Article - sowenatedzonedotnet - 1 Feb 2008 - 7:32pm - 0 comments - 0 attachments - 2 groups

Shared SCSI Two-Node Cluster

... hardware solution that can do shared SCSI with RAID . It happens that I have done this with very specific hardware, which ... SCSI hard drives. Dell also sells an appropriate RAID controller, the PERC 4DC or 4eDC controller line (The e stands for PCI ...

Article - geoffc - 12 Jan 2008 - 2:02am - 0 comments - 0 attachments - 2 groups