Sök

Search results

eDirectory Disaster Recovery

... files: SERVDATA.NDS DSMISC.LOG VOLSINFO.TXT STARTUP.NCF AUTOEXEC.NCF TID 10062402 ( ...

Article - dgersic - 22 Jul 2010 - 2:39pm - 1 comment - 0 attachments - 2 groups

NetWare Physical to Virtual (P2V) Conversion Process With Free Tools

... to the old server hardware) loaded in the servers STARTUP.NCF Add a line to load a suitable VMware disk device driver in the STARTUP.NCF Start the server with no autoexec.ncf execution Use ...

Article - gavo - 13 Oct 2009 - 2:33pm - 11 comments - 1 attachment - 2 groups

GroupWise 7.02 Webaccess stops working on NW65SP2

... the BIOS . Rem'd out "c:\acpidrv.psm" out of the startup.ncf file. Now apache2.nlm would load but would receive page fault ...

Article - jmfuge - 5 Aug 2008 - 8:56am - 0 comments - 0 attachments - 3 groups

NetWare Server Migration Physical to Virtual (P2V) using VMware

... for VMware's virtual devices. Before modifying STARTUP.NCF and AUTOEXE.NCF, make backup copies of them. NetWare 5.1, 6.0 ... and AUTOEXEC.NCF for each version: NetWare 5.1 – STARTUP.NCF: LOAD MPS14.PSM LOAD IDECD.CDM LOAD IDEHD.CDM LOAD IDEATA.HAM ...

Article - cparker - 17 Mar 2008 - 6:54pm - 4 comments - 1 attachment - 2 groups

Success with Clustering GroupWise: A Guide to Building a Highly Available GroupWise System

... its file system , you placed parameters in the STARTUP.NCF or the AUTOEXEC.NCF. Well, this is not the case with NSS. ... This section is just for the benefit of NetWare 6.0. STARTUP.NCF Parameters There are a few SET commands that need to be set ...

Article - GreggHinchman - 29 Feb 2008 - 9:06am - 0 comments - 0 attachments - 3 groups

GroupWise Clustering Basics: Part 2

... Patches NSS Configuration Parameters STARTUP.NCF Parameters Cluster Hardware Design This is a great ... efficiently for GroupWise with OES NetWare. STARTUP.NCF Parameters There are a couple SET commands that need to be set ...

Article - GreggHinchman - 29 Feb 2008 - 7:03am - 0 comments - 0 attachments - 3 groups

Solving Error: NDMP Error NDMP_NO_DEVICE_ERR (16)...

... load EDIT, press INS key, and browse to C:\NWSERVER\ STARTUP.NCF and look for the HAM driver command. Note the slot ...

Article - cnejack - 25 Jan 2008 - 12:53pm - 0 comments - 0 attachments - 2 groups

Memory Tuning Calculator for NetWare 6.5

... cache size. All values other than EC go into the STARTUP.NCF - not AUTOEXEC.NCF. Make sure none of the values are also being ... This is because?.. . When setting the values, put them in STARTUP.NCF and also set them from the server console , then reboot the ...

Tool - Hspeirs - 20 Dec 2007 - 12:20pm - 0 comments - 0 attachments - 0 groups

DOS Boot Menu for NetWare

... \NWSERVER cls @echo Start NetWare with No Logo (-nl), no STARTUP.NCF (-NS), @echo and no AUTOEXEC.NCF (-NL) @echo Use Loadstage # (enter) commands to progress @echo 1. startup.ncf @echo 2. loadstage 1, mounts sys @echo 3. loadstage 2 ... 4 @echo ...

Article - rudd_j - 19 Dec 2007 - 10:22am - 0 comments - 0 attachments - 2 groups

NW65 Memory Tuning NLM

... files: c:\ autoexec.bat c:\nwserver\startup.ncf sys:system\ autoexec.ncf sys:_netware\_ndsdb.ini ...

Tool - Hspeirs - 24 Jan 2007 - 3:27pm - 0 comments - 0 attachments - 0 groups