Novell Home

Can't find error codes

Novell Cool Solutions: Question & Answer

Posted: 25 Aug 2004

Q:
I got an NAAS error code 7002 when trying to run a report, but I can't find that error code anywhere in the online docs for Novell Audit.

A:
NAAS is a discontinued product. A few new error codes have been created since the time the NAAS Admin Guide was written, and the following error codes have not been incorporated into the online documentation:

1. Error code: 7202
Possible cause: Insufficient Rights for Auditor.
Action: Assign the read rights for naasTrail on the NAAS Server object. Then, close the ConsoleOne and try again.

2. Error code: 7504
Possible cause:Unable to read the NAAS server certificate from Novell eDirectory.
Action: Check whether the Auditor is assigned with read rights for the key material object, NAASKMO and naasTrail on the NAAS server object. Assign the rights if not assigned. Then, close the ConsoleOne and try again.

3.Error code: 7510
Possible cause: Error while reading the NAAS server parameters.
Action:
1. Make sure that the NAAS is up and running.
2. Check whether Auditor is assigned with read rights for naasPortNumber, HostDevice, NAASKMO and naasTrail on the NAAS server object. Assign the rights if not assigned. Close the ConsoleOne and try again.

4. Error code 7511:
Possible cause: The user name and password entered by the user are incorrect.
Action:Make sure that the correct user name and password are entered and try again.

5. Error code 7512:
Possible cause: Internal error.
Action:Restart the NAAS Server and client and try again.

Novell Cool Solutions (corporate web communities) are produced by WebWise Solutions. www.webwiseone.com