Previous Page: FRTRACE 1.10 68: Unable to get message pointer.  Next Page: FRTRACE NUT Errors

FRTRACE 1.10 75: NUT Initialization Error (return value=value).

Source:  FRTRACE-1.10

Explanation:  Error encountered in TUI Initialize function. This error usually occurs when the server is low on memory or the Textual User Interface (TUI) version is not compatible with the FRTRACE version. TUI prints out an additional message explaining the reason for the failure.

Action:  Use NetWare Administrator or MONITOR to determine whether the server is low on memory. If the server is low on memory, refer to Resolving Memory Problems. Reload FRTRACE when more memory is available. If the server is not low on memory, TUI and FRTRACEare probably not compatible versions. Record the version numbers of TUI and FRTRACE, then contact technicalsupport. To check the version number, enter module module_name at the console. For example, enter module TUI at the console to get the version number for TUI.

  Previous Page: FRTRACE 1.10 68: Unable to get message pointer.  Next Page: FRTRACE NUT Errors