NetWare Link/X.25 Link Layer Characteristics
The NetWare Link/X.25 Link layer conforms to the X.25 LAPB procedure and to the HDLC framing format. The NetWare Link/X.25 Link layer has the following characteristics:
- Modulo 8 or 128 numbering scheme
- User-defined window size 1 and 7 (or 1 and 127 for modulo 128 numbering)
- Automatic flow control through RNR frames in case of X.25 overload
- User-configurable retransmission timer (T1)
- User-configurable maximum retransmission counter (N2)
- User-configurable maximum number of bits in an Information (I) frame (N1)
- Automatic frame retransmission in case of transmission errors
- ITU-T 1976, 1980, 1984, 1988 compliance, except for the multilink procedure