Previous Page: FILESYS-X-519: Station number file lock threshold exceeded. Total violations number.  Next Page: FILESYS-X-521: Station number record lock threshold exceeded. Total violations number.

FILESYS-X-520: System record lock threshold exceeded. Number record lock requests failed.

Source:  FILESYS.NLM

Explanation:  The number of record locks on the server exceeded the maximum specified. Applications that lock records will not function properly. The number in the message indicates the total number of record lock requests for the station that failed because the limit was exceeded.

Action:  Increase the number of system record locks using the SET console command. For the syntax and value required, see the parameters for the SET comand SET MAXIMUM RECORDS LOCKS.

Increasing the number of record locks will increase the amount of memory required by the server. You might need to increase the available memory on the server. Increase the memory available to the server. See "Freeing Server Memory Temporarily in the Server Operating System Administration Guide.



  Previous Page: FILESYS-X-519: Station number file lock threshold exceeded. Total violations number.  Next Page: FILESYS-X-521: Station number record lock threshold exceeded. Total violations number.