890F   Connection no longer valid

Source:  GroupWise engine; TCP/IP communication.

Explanation:  Connection was broken while in use.

Possible Cause:  A client or server machine has crashed, or the process was forced to close without shutting down. The machine might have been exited while connections were active.

Action:  Make sure the POA is running. Check the IP address for the POA. See "Using Client/Server Access to the Post Office" in "Post Office Agent" in the GroupWise 6.5 Administration Guide.

Possible Cause:  The GroupWise client is trying to use client/server mode to connect with the POA, but the POA is not set up for client/server processing.

Action:  Configure the POA for client/server processing to match the needs of the client. See "Using Client/Server Access to the Post Office" in "Post Office Agent" in the GroupWise 6.5 Administration Guide.

Possible Cause:  If this error appears in the Message Transfer Status box of the POA, the MTA to which it is transferring messages is not running.

Action:  Check the status of the MTA for the domain. Restart the MTA if necessary.

Action:  Record the conditions under which you encountered the error. For the latest error code solutions, search for TIDs about the error code in the Novell Support Knowledgebase .