Possible Cause: One or more machines in the network are assigned more than one IP address and are bound to the same MAC address. ZENworks Server Management assumes that the two networks are running on the same segment.
Action: Check the properties of the machines in ConsoleOne to see if machines having more than one IP address are connected to a single MAC address. You need to reconfigure the machines correctly and run discovery again with an empty database.
WARNING: The configuration information about alarms, health reports, etc., is lost If you copy an empty database.
Possible Cause: The data (*.btv) files in the installvolume:\installdirectory\zenworks\mms\nmdisk\ipcache directory are corrupted. The *.btv files are temporary files, which are possibly corrupted because of a server abend.
Action: Perform the following tasks:
Possible Cause: NXPIP discovery is not running. The status is displayed as Not Loaded in NXPCON.