Source: Remote Control Listener
Severity: Informational
Explanation: The Remote Control Listener cannot bind to the port number specified in ConsoleOne_installation_directory\1.2\bin\rmports.ini because it is used by another application.
Possible Cause: This error occurs when you invoke ConsoleOne® across multiple sessions of a terminal server. The current release of ZENworks 6.5 Remote Management does not support the Remote Control Listener across multiple terminal server sessions.
Action: Close ConsoleOne on all sessions and restart it in the current session.
Possible Cause: Another application might be using the port required by the Remote Control Listener.
Action: The Remote Control Listener must listen on a unique port number, which should not be used by any other application. You can either change the port number of the Remote Control Listener or that of the other application.
To change the port number on which the Remote Control Listener listens:
Enter the port number in the rmports.ini file in the consoleone_installation_directory \ bin directory.
Restart ConsoleOne.
On the managed server, edit the rmcfg.ini file in the ZENworks_agent_installation_directory\rmagent directory
In the Remote Control Listener Ports section, specify the port number provided in Step 1.
Restart the Novell ZENworks Remote Management service.