Novell Home

My Favorites

Close

Please to see your favorites.

Re-installing the DeFrame Active X Controls.

(Last modified: 10Feb2003)

This document (10065204) is provided subject to the disclaimer at the end of this document.

goal

Re-installing the DeFrame Active X Controls.

Remove and re-install the Deframe plugins to the workstation.

Removing DeWk 2.0.

fact

Novell DeFrame 2.0

fix

Follow these steps to remove and re-install the DeWk 2.0 component from a workstation:

1- Add/Remove programs - Remove DeWk 2.0.

2- Remove the RDP ActiveX controls if the RDP component is being used by going to a DOS prompt to the system directory (c:\windows\system on 9x or c:\winnt\system32 on NT/2K) type:

regsvr32 axdappx.ocx /u

3- Remove the ICA ActiveX controls if the ICA component is being used by going to a DOS prompt to the system directory (c:\windows\system on 9x or c:\winnt\system32 on NT/2K) type:

regsvr32 axdappxica.ocx /u

4-Delete the following files from the system directory:
axdappx.ocx
axdappxica.ocx
dappx.dll
conman.exe
mstsc.exe

5- Delete c:\windows\system\dappx or c:\winnt\system32\dappx directory

6- Re-install the wksetup.exe or re-launch the browser so the plugins from sys:\ondemand\webapp\web\bin get re-installed to the workstation.  In the sys:\ondemand\webapp\web\bin folder, the ActiveX plugins (for Internet Explorer) end with a .cab extension, the Netscape plugin files end with a .jar extension.

disclaimer

The Origin of this information may be internal or external to Novell. Novell makes all reasonable efforts to verify this information. However, the information provided in this document is for your information only. Novell makes no explicit or implied claims to the validity of this information.
Any trademarks referenced in this document are the property of their respective owners. Consult your product manuals for complete trademark information.

  • Document ID:
  • 10065204
  • Solution ID: NOVL60086
  • Creation Date: 08Oct2001
  • Modified Date: 10Feb2003
    • NovellConnectivity Products

      Management Products

Did this document solve your problem? Provide Feedback