Administrative messages are not flowing properly

This document (7002585) is provided subject to the disclaimer at the end of this document.

Environment

Novell GroupWise 6
Novell GroupWise 6.5
Novell GroupWise 7
Novell GroupWise 8

Situation

Administrative messages are not flowing properly
Administrative messages do not flow to the post office database.
Error:  Object needs to be synchronized: DB20
Error:  D506
There is a domain database (WPDOMAIN.DB) in the post office directory or vice versa.  The POA or MTA would attempt to update the wrong database.

Resolution

Insure that the domain and post office directory do not contain a WPDOMAIN.DB and a WPHOST.DB.  This has been known to cause some very strange issues.  The domain directory will contain a WPDOMAIN.DB but should not contain a WPHOST.DB and vice versa.

Additional Information

Formerly known as TID# 10081062

Disclaimer

This Support Knowledgebase provides a valuable tool for NetIQ/Novell/SUSE customers and parties interested in our products and solutions to acquire information, ideas and learn from one another. Materials are provided for informational, personal or non-commercial use within your organization and are presented "AS IS" WITHOUT WARRANTY OF ANY KIND.