Novell Home

My Favorites

Close

Please to see your favorites.

Every incremental sync job for a Windows workload switches to server sync method

This document (7007326) is provided subject to the disclaimer at the end of this document.

Environment

Windows workload protected with block-based transfer method.

Platespin Protect 10.x
Platespin Forge 3.x

Situation

Windows workload protected with block-based transfer method. Full sync job completes fine while subsequent incremental sync jobs complete with following warning(s):

"Block Based Driver communication failure"
"There was a problem monitoring volume changes after the last synchronization period. The Incremental Synchronization was switched to Server Sync Mode."



Resolution

1. Uninstall Block-based driver from source manually (refer to TID 7005616) and reboot the machine.

2. Run another incremental sync job which will install the driver during the job OR install driver manually (refer to TID 7010094) on source workload and reboot the machine.

Note: TIDs referred to above are internal documents. Please contact Novell Technical Support to obtain information documented in these TIDs.

Cause

This could happen for newly protected workload or workload which was previously protected with an older version of Platespin PortabilitySuite/Protect using VSS-BBT method and upgraded to a newer version in which driver version changed.

The underlying reason is that the driver is not properly/completely installed and unable to monitor all volumes for changes. This could happen due to one of the following reasons:

1. Source not rebooted after block driver install.
2. A change in source volumes since driver was installed.
3. Block driver installation being corrupted.

Disclaimer

This Support Knowledgebase provides a valuable tool for NetIQ/Novell/SUSE customers and parties interested in our products and solutions to acquire information, ideas and learn from one another. Materials are provided for informational, personal or non-commercial use within your organization and are presented "AS IS" WITHOUT WARRANTY OF ANY KIND.

  • Document ID:7007326
  • Creation Date:18-MAY-12
  • Modified Date:22-MAY-12
    • NetIQPlateSpin Forge
      PlateSpin Portability Suite
      PlateSpin Protect

Did this document solve your problem? Provide Feedback