Environment
Situation
X2P migration to a target machine with a Broadcom HT1000 series SATA controller will go into recoverable error during the Configure Target Machine step.
Due to a driver signing issue with the Broadcom HT1000 series SATA controller drivers, target physical machine may fail to boot up correctly. The problem is with the file "bchtsw64.sys". This will result in the job going into recoverable error during the Configure Target Machine step. The target machine will display the following error:
"Unable to verify the digital signature of the file"
Resolution
4. Repeat steps 2-5 until the "Configure Target Machine" step has completed the "Installing Drivers" step.
You may be required to do this 1 to 4 times. After this process, target machine should have no problems booting up.
Note: The job might or not recover from the current error state. However, once the target is up and functional as expected, the job is considered complete. It can be aborted to move it to failed state.