DSfW: ADC Install fails during the health check

This document (7012150) is provided subject to the disclaimer at the end of this document.

Environment

Novell Open Enterprise Server 11 SP1 (OES11SP1)
Domain Services for Windows
DSfW

Situation

Install an additional domain controller to an existing DSfW domain.
The provisioning fails with following error in remote server health check task:

[12:58:49, Thu Sep 27, 2012, 1]: Failed, the output is [Cannot connect to
server.  Error was NT_STATUS_CONNECTION_INVALID]  
[12:58:49, Thu Sep 27, 2012, 1]: RPC and Samba Service health check failed :
Cannot connect to server.  Error was NT_STATUS_CONNECTION_INVALID: 256  
[12:58:49, Thu Sep 27, 2012, 0]: The remote server health check failed <104> 
[12:58:49, Thu Sep 27, 2012, 0]: The health check failed. <104>

Resolution

Fixed in April 2013 Maintenance Patch

Additional Information

Contact Novell Support for a FTF for January 2013 Maintenance Patch if this fix is needed before the release of the April Maintenance Patch.

Disclaimer

This Support Knowledgebase provides a valuable tool for NetIQ/Novell/SUSE customers and parties interested in our products and solutions to acquire information, ideas and learn from one another. Materials are provided for informational, personal or non-commercial use within your organization and are presented "AS IS" WITHOUT WARRANTY OF ANY KIND.