31021 error eventid after upgrading to 6.5.4 of Security Manager

This document (7012189) is provided subject to the disclaimer at the end of this document.

Environment

NetIQ Security Manager 6.5.4

Situation

After upgrading to 6.5.4, the NetIQ Security Manager service will not start.
 
Error that shows up in the Windows NT Application Log:  
31021 error:  Could not locate registry entry for Log Manager component.   Registry Key: SOFTWARE\NetIQ\Security Manager\DASServer Value Name: DataSource

Resolution

For 32 bit windows servers, add 2 reg keys to HKEY_LOCAL_MACHINE\SOFTWARE\NetIQ\Security Manager\DasServer
  1. Database
    • String Value
    • Should contain the name of the OnePoint database.
  2. Datasource
    • String Value
    • Should contain the name of the SQL server (including named instance if it's not the default) hosting the OnePoint database.
For 64bit windows servers, the keys are the same, but the path is HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\NetIQ\Security Manager\DasServer
 
Once done, restart all the NetIQ Security Manager services.
 
*If either is incorrect, the service will fail with several DAS errors as it will be unable to contact the database properly.

Disclaimer

This Support Knowledgebase provides a valuable tool for NetIQ/Novell/SUSE customers and parties interested in our products and solutions to acquire information, ideas and learn from one another. Materials are provided for informational, personal or non-commercial use within your organization and are presented "AS IS" WITHOUT WARRANTY OF ANY KIND.