Unable to complete Nightly Maintenance

This document (7012712) is provided subject to the disclaimer at the end of this document.

Environment

Novell Data Synchronizer Mobility Pack

Situation

Nightly Maintenance goes through one user, immediately stops: nightly maintenance could not remove all the orphaned attachments because the time is up or the connector is stopped.
Nightly Maintenance fails overnight, not finishing or completing.
Start/Stop time cannot cross midnight to the end time.

Resolution

  1. Reconfigure /etc/datasync/configengine/engines/default/pipelines/pipeline1/connectors/mobility/connector.xml:
    <databaseMaintenanceStartHour>0</databaseMaintenanceStartHour> <databaseMaintenance>1</databaseMaintenance> <databaseMaintenanceStopHour>23</databaseMaintenanceStopHour>

  2. Restart DataSync services:
    rcdatasync restart

Cause

Start/Stop time for Nightly Maintenance cannot cross midnight to the end time.

Status

Reported to Engineering

Disclaimer

This Support Knowledgebase provides a valuable tool for NetIQ/Novell/SUSE customers and parties interested in our products and solutions to acquire information, ideas and learn from one another. Materials are provided for informational, personal or non-commercial use within your organization and are presented "AS IS" WITHOUT WARRANTY OF ANY KIND.