Novell Home

My Favorites

Close

Please to see your favorites.

Imaging device boot delayed at PXE connection closure

This document (7012899) is provided subject to the disclaimer at the end of this document.

Environment

Novell ZENworks Configuration Management 11.2 Imaging

Situation

Devices boot with ZENworks PXE and get delayed by up to 30 seconds after showing the message
"Contacting Novell Preboot Policy Service...Done".

Resolution

This is fixed in version 11.2.4 - see TID 7012027 "ZENworks Configuration Management 11.2.4 - update information and list of fixes" which can be found at http://www.novell.com/support/search.do?usemicrosite=true&searchString=7012027

Cause

Device waits but does not receive the acknowledgement packet of PXE the connection getting closed from the imaging server. At this stage the device would not need to wait for this acknowledgement since the connection closure got triggered by the device.

Disclaimer

This Support Knowledgebase provides a valuable tool for NetIQ/Novell/SUSE customers and parties interested in our products and solutions to acquire information, ideas and learn from one another. Materials are provided for informational, personal or non-commercial use within your organization and are presented "AS IS" WITHOUT WARRANTY OF ANY KIND.

  • Document ID:7012899
  • Creation Date:18-JUL-13
  • Modified Date:06-NOV-13
    • NovellZENworks Configuration Management

Did this document solve your problem? Provide Feedback