My Favorites


Please to see your favorites.

Imaging device boot delayed at PXE connection closure

This document (7012899) is provided subject to the disclaimer at the end of this document.


Novell ZENworks Configuration Management 11.2 Imaging


Devices boot with ZENworks PXE and get delayed by up to 30 seconds after showing the message
"Contacting Novell Preboot Policy Service...Done".


This is fixed in version 11.2.4 - see TID 7012027 "ZENworks Configuration Management 11.2.4 - update information and list of fixes" which can be found at http://www.novell.com/support/search.do?usemicrosite=true&searchString=7012027


Device waits but does not receive the acknowledgement packet of PXE the connection getting closed from the imaging server. At this stage the device would not need to wait for this acknowledgement since the connection closure got triggered by the device.


This Support Knowledgebase provides a valuable tool for NetIQ/Novell/SUSE customers and parties interested in our products and solutions to acquire information, ideas and learn from one another. Materials are provided for informational, personal or non-commercial use within your organization and are presented "AS IS" WITHOUT WARRANTY OF ANY KIND.