double pop-up with reboot/shutdown action in bundle

  • 7009788
  • 23-Nov-2011
  • 27-Apr-2012

Environment

Novell ZENworks 11 Configuration Management Support Pack 1 - ZCM 11 SP1 Bundles

Situation

When executing a bundle with a reboot/shutdown action, 2 pop-ups are being displayed instead of 1.

The following 2 conditions have to be met:
  1. There must be an action present within the install tab which run in the security context "Run as dynamic administrator"
  2. The reboot message time out must set to "-1" (wait an indefinite period of time)

Resolution

This is fixed in version 11.2 - see KB 7010044 "ZENworks Configuration Management 11.2 - update information and list of fixes" which can be found at https://www.novell.com/support