OES2 - 2-Node Cluster SBD detection algorithm discrepancies
This document (3767762) is provided subject to the disclaimer at the end of this document.
Environment
Novell Open Enterprise Server 2 (i386/x86_64)
Novell Cluster Services
Situation
In a test scenario where the LAN Cable is pulled from the node having the Master IP address, eventually the voting mechanism needs to determine the node with the proper Link status to survive. The observed behavior on OES2 x86_64 however is that the Master node does not detect the Link Status loss, and as such will not be cast out of the cluster.
For more information on Split Brain Detection, see the TID 1005388 - Gory details of Heartbeats, Split Brains and Poison Pills
Resolution
Status
Reported to EngineeringAdditional Information
Customers running OES environments using 3COMs with the 3c5x9 lan driver are still vulnerable to the problem as the driver for the card is too slow to update it's link status. Considering the mentioned limitation of the mentioned 3c5x9 network drivers in Novell Open Enterprise Server cluster environments alternatives to this specific card need to be considered.
Document
| Document ID: | 3767762 |
| Creation Date: | 03-03-2008 |
| Modified Date: | 12-24-2008 |
| Novell Product: | Cluster Services |
| Novell Product: | Open Enterprise Server |
| Novell Product: | SUSE Linux Enterprise Server |
Disclaimer
The Origin of this information may be internal or external to Novell. Novell makes all reasonable efforts to verify this information. However, the information provided in this document is for your information only. Novell makes no explicit or implied claims to the validity of this information.
Any trademarks referenced in this document are the property of their respective owners. Consult your product manuals for complete trademark information.