APPLETLK-5.11-1251: Inconsistent zone name. AppleTalk will use the same zone name for the SFT3 network as configured on the SFT3 primary machine.
Source: APPLETLK-5.11
Explanation: AppleTalk was configured with different zone names for the SFT III Network in the two SFT III IOEngines.AppleTalk should be configured with the same SFT III Network number and zone in both IOEngines. AppleTalk will ignore the zone name configured in the secondary IOEngine, and use only the SFT III Network zone name configured in the primary IOEngine.
Action: If the SFT III Network zone name currently configured in the primary IOEngine is correct, no action is required. Otherwise, use NIASCFG, select Configure NIAS > Protocols and Routing, to configure the zone name correctly and reinitialize the server or router in both IOEngines. Even if no current action is required, you should use NIASCFG to configure the two IOEngines correctly.
![]() |