Incorrect ISD Data is populated when doing local imaging from a ZENworks Partition

This document (7012832) is provided subject to the disclaimer at the end of this document.

Environment

Novell ZENworks Configuration Management 11.2 Imaging

Situation

On a device that has a ZENworks Partition (see Managing ZENworks Partitions in ZENworks 11 SP2 Preboot Services and Imaging Reference), after doing a restore operation from a local image:
  1. Last base Image time is not updated
  2. Last Base Image size is shown as a negative number

Resolution

This is fixed in version 11.2.4 - see TID 7012027 "ZENworks Configuration Management 11.2.4 - update information and list of fixes" which can be found at http://www.novell.com/support/search.do?usemicrosite=true&searchString=7012027

Disclaimer

This Support Knowledgebase provides a valuable tool for NetIQ/Novell/SUSE customers and parties interested in our products and solutions to acquire information, ideas and learn from one another. Materials are provided for informational, personal or non-commercial use within your organization and are presented "AS IS" WITHOUT WARRANTY OF ANY KIND.