Novell is now a part of Micro Focus

My Favorites

Close

Please to see your favorites.

A workspace or folder stops showing up in the Navigation Panel of Vibe due to re-index errors

This document (7022466) is provided subject to the disclaimer at the end of this document.

Environment

Micro Focus Vibe 4.0.3
Micro Focus Vibe 4.0.2
Novell Vibe 4.0.1
Novell Vibe 4.0

Situation

A workspace or folder stops showing up in the Vibe Navigation Panel.  When an admin goes to "Configure Views, URLS and Controls", it shows up, but is hidden when looking at the Navigation Panel.
Re-indexing the workspace or folder results in an error.

In addition, the following message is seen in appserver.log when re-indexing the workspace or folder.

[org.kablink.teaming.module.folder.impl.DefaultFolderCoreProcessor] - Error indexing entry: (Entry_ID)


e.g:

2017-04-03 10:19:02,213 ERROR [http-bio-80-exec-116-(2-1491228724108)] [org.kablink.teaming.module.folder.impl.DefaultFolderCoreProcessor] - Error indexing entry: (121456) John Doe
java.lang.NullPointerException

2017-04-11 18:56:58,758 ERROR [http-bio-80-exec-9-(1-1491951405547)] [org.kablink.teaming.module.folder.impl.DefaultFolderCoreProcessor] - Error indexing entry: (2438)
java.lang.ClassCastException: org.kablink.teaming.domain.Event cannot be cast to java.util.Date

Resolution

A fix for this issue is available for Vibe 4.0.2 -Patch 2. Please contact Micro Focus Customer Care with reference to this TID for further assistance.

Disclaimer

This Support Knowledgebase provides a valuable tool for NetIQ/Novell/SUSE customers and parties interested in our products and solutions to acquire information, ideas and learn from one another. Materials are provided for informational, personal or non-commercial use within your organization and are presented "AS IS" WITHOUT WARRANTY OF ANY KIND.

  • Document ID:7022466
  • Creation Date:16-DEC-17
  • Modified Date:16-DEC-17
    • NovellVibe

Did this document solve your problem? Provide Feedback