Automatic Imaging Fails with Large Image-safe Data.

  • 3330677
  • 27-Feb-2007
  • 30-Apr-2012

Environment


Novell ZENworks 7 Desktop Management - Support Pack 1 - ZDM7 PreBoot Services (PXE)
Novell ZENworks 7 Desktop Management - Support Pack 1 - ZDM7 Imaging

This is not an issue if ZENworks Imaging Services are running on a Linux backend.

Situation

If ZENworks Image-safe Data (ZISD) is large in size then automatic imaging fails to work.

Resolution

Fixed in ZENworks 7 Desktop Management Service Pack 1 Interim Release 3a, available at Novell Downloads

Additional Information

Error:"PXE_HARDWARE_SIGNATURE invalid" can be seen in the DTS.LOG.

To enable the DTS log:
1) Change the value of "MustLog" to "1" within the file SYS:SYSTEM\DTS.INI
2) unload dts.nlm
3) load dts.nlm

The log file can be found in SYS:SYSTEM\DTS.LOG