3.1 90xx Errors

NOTE:This guide does not include a comprehensive list of all possible GroupWise error codes. It lists error codes for which solutions are readily available from GroupWise engineers and testers. You can search the Novell Support Knowledgebase to locate additional solutions documented by Novell Support as specific customer issues have been resolved.

9007 Client not set up for SSL

Source: GroupWise engine; client/server.
Explanation: The POA is configured to require SSL communicate with the GroupWise client, but the client is not capable of SSL communication.
Possible Cause: SSL communication was introduced for the GroupWise client in GroupWise 6.5. You are running an older GroupWise client against a post office that has been updated to GroupWise 6.5 or later.
Action: Update the client to GroupWise 6.5 or later.
Action: Reconfigure the POA so that SSL is enabled rather than required. See Securing the Post Office with SSL Connections to the POA in Configuring the POA in the GroupWise 2012 Administration Guide.

9008 Server does not support SSL

Source: GroupWise engine; client/server.
Explanation: The GroupWise client is trying to use an SSL connection to the POA but the POA is not configured for SSL.
Possible Cause: The POA has been reconfigured without SSL since the client logged in.
Action: Restart the GroupWise client. It does not try to use SSL when it detects that the POA is not configured for SSL.