65.0 SPXS Messages

The following includes messages from SPXS.NLM.

SPX-X-5: There is insufficient memory for allocation.

Source: SPXS.NLM
Explanation: SPXII was unable to allocate the requested amount of memory for the Protocol ID table or the board registration table.
Possible Cause: The server does not have enough available memory.
Action: Increase the memory available to the server. See Freeing Server Memory Temporarily in the NW 6.5 SP8: Server Operating SystemAdministration Guide.

SPX-X-6: There insufficient memory for allocation.

Source: SPXS.NLM
Explanation: SPXII was unable to allocate the requested amount of memory for the Protocol ID table or the board registration table.
Possible Cause: The server does not have enough available memory.
Action: Increase the memory available to the server. See Freeing Server Memory Temporarily in the NW 6.5 SP8: Server Operating SystemAdministration Guide.

SPX-X-7: SPXII cannot be configured.

Source: SPXS.NLM
Explanation: An attempt was made to configure SPXII, but SPXII parameters cannot be configured.

SPX-X-9: There is no LAN board registered with LSL.

Source: SPXS.NLM
Explanation: An attempt was made to load SPXS before loading a network board. The operating system must have a board registered with the LSL with a valid IPX and SPX frame type to initialize SPXS.
Action: Load a network board. Then load SPXS again.

SPX-X-10: The name device cannot be loaded by STREAMS.

Source: SPXS.NLM
Explanation: This message is probably preceded by error messages from the STREAMS module.
Possible Cause: The user specified a duplicate or invalid device name.
Action: Make sure that the specified device name is valid, and is not a duplicate.
Possible Cause: The user is trying to load too many devices.
Action: Refer to any preceding error messages to help determine the exact cause of the problem.

SPX-X-11: The name device cannot be loaded by STREAMS.

Source: SPXS.NLM
Explanation: This message is probably preceded by error messages from the STREAMS module.
Possible Cause: The user specified a duplicate or invalid device name.
Action: Make sure that the specified device name is valid, and is not a duplicate.
Possible Cause: The user is trying to load too many devices.
Action: Refer to any preceding error messages to help determine the exact cause of the problem.

SPX-X-12: Module_name STREAM module still in use. Unloading will have unknown consequences.

Source: SPXS.NLM
Explanation: The indicated module is currently being referenced by another NLM program or IntranetWare driver. Unloading the module while it is being used might produce unwanted results.
Action: Wait until the module is not being used. Then try the unload again.

SPX-X-16: SPXS requires STREAMS version version to operate correctly; initialization unable to complete. Please load correct version of STREAMS.NLM before attempting to reload SPXS.

Source: SPXS.NLM
Possible Cause: The server is not using the correct version of stream.nlm.
Action: Get a current version of stream.nlm