The Action - Reboot/Shutdown dialog box lets you specify the reboot or shutdown action for the device. You can also specify the specific requirements that a device must meet for the action to be executed on the device.
Figure 6-28 Action - Reboot/Shutdown Dialog Box
To access this dialog box in ZENworks Control Center, click the
tab. Click the underlined link of a bundle in the column of the list, click the tab, click one of the action set tabs (Distribute, Install, Launch, Verify, Uninstall, Terminate, or Preboot), click the drop-down list, then select an available action.NOTE:The Reboot action should not normally be used in conjunction with a Recurring launch schedule set to
. Although there are some valid use scenarios for this configuration, scheduling a device to reboot upon refresh can cause a continuous loop.The following sections contains additional information:
The General page lets you specify the reboot or shutdown action for the device.
Reboot the device when this action is performed.
Shut down the device when this action is performed.
Specify the number of seconds (between -1 and 1800) before the device reboots or shuts down. When the number of seconds specified passes, the device reboots or shuts down, regardless of whether the user clicks
or not. Clicking does not cause the device to immediately reboot or shut down.A value of -1 causes the device to wait an indefinite period of time, essentially preventing the device from rebooting or shutting down. You should use a value of -1 in conjunction with the
and, optionally, the options. If you specify -1 and select the option, a message displays indefinitely until the user clicks to perform the reboot or shutdown process. If you select both this option and the option, a message displays indefinitely until the user clicks or .A value of -1 causes the device to wait an indefinite period of time, essentially preventing the device from rebooting or shutting down. You should use a value of -1 in conjunction with the
and, optionally, the options. If you specify -1 and select the option, a message displays indefinitely until the user clicks to perform the reboot or shutdown process. If you select this option and the option, a message displays indefinitely until the user clicks or .Specify that a message displays on the device, warning the user that the device is going to reboot or shut down.
For example, you could provide the following prompt:
The machine will reboot in _ seconds. Please save your work and close any open applications.
Before performing the action, the message displays on the device only if the user is logged in.
Specify whether the user can cancel the reboot or shutdown procedure.
Define the prompt that you want to display on the device. Additionally, you can specify different locales with different messages. If you do not specify another locale, a default English message displays.
To create a message:
Click
to display the dialog box.Select a language from the
drop-down list. The message displays only on devices in the specified locale. You can create different messages, each with its own locale setting.Type the text you want to display on the device.
You can include {0} in your text to provide a running counter that counts down the number of seconds to 0, after which the prompt is auto-accepted. For example, you could specify the following text:
The machine will reboot in {0} seconds. Please save your work and close any open applications.
The message displays for the number of seconds specified in the
field.Click
.The Requirements page lets you define specific requirements that a device must meet for the action to be enforced on it. For information about the requirements, see Requirements.