Inventory Scanner Error Messages on NetWare Servers

2001: Unable to open the log file filename. Error code = error_code
2002: The initialization file filename is not found. Unable to start Inventory scanning
2003: Unable to load initialization file filename. Inventory scanning will not proceed
2004: The initialization file filename has been successfully loaded
2005: Registration with the SNMP Manager Interface Entity layer failed. The error is message. Ensure that SNMP.NLM is loaded and operational
2006: SNMP Manager Interface Entity Layer information: message scan status = message
2007: API results: message error code = error_code
2008: An import error in message information. Error code = error_code. The mapping files might have changed. Restore the original mapping files
2009: Intermediate file information: the possible problem is message
2010: Unable to read the initialization file filename. Inventory scanning will not proceed
2011: Unable to load the contents of the file filename. Inventory scanning will not proceed
2012: Unable to read the mapping file filename. The Inventory scanning results may not be accurate
2013: An internal error message occurred in the API interface. The mapping files might have changed. Restore the original mapping files
2014: An internal error message occurred in the SNMP interface. The mapping files might have changed. Restore the original mapping files
2015: Unable to write the internal system ID and .str filename to a persistent store
2016: Unable to read the internal system ID from the persistent store. If this error persists, for more information see the ZENworks 6.5 Server Management error message documentation at http://www.novell.com/documentation
2017: An internal error occurred in NWUSStandardUnicodeInit. Error code = error_code
2018: An internal error occurred in NWUSByteToUnicode. Error code = error_code
2019: An internal error occurred in NWUSUnicodeToByte. Error code = error_code
2020: Unable to procure qualified DN and Tree name. Error code = error_code
2021: Unable to import symbol from MPKSCAN.NLM. Software inventory scanning will not be done
2022: Hardware scanning failed. The Inventory scan results will not be available
2023: Unable to generate the .str file. Error code = error_code. The Inventory scan results will not be available
2024: Unable to create the .str file. Error is message. The Inventory scan results will not be available
2025: Software scanning failed. Error code = error_code. The software inventory scan results will not be available
2028: An internal error occurred. Unable to initialize the hardware classes
2029: Unable to continue scanning. Load the MPKSCAN.NLM software inventory helper application
2030: Scanning terminated unsuccessfully. The inventory scan results will not be available
2031: Unable to unload the MPKSCAN.NLM software inventory helper application
2032: The hardware inventory helper application, INVAID.NLM was not loaded. System Management (SMBIOS) hardware inventory will not be available
2033: An internal error occurred in the INVAID.NLM hardware inventory helper application. System Management (SMBIOS) hardware inventory will not be available
2034: Unable to unload the INVAID.NLM hardware inventory helper application
2035: An internal error occurred in NWUXLoadByteUnicodeConverter. Error code = error_code
2036: Unable to read the .str filename from the persistent store. If this error persists, for more information see the ZENworks 6.5 Server Management error message documentation at http://www.novell.com/documentation
2037: Unable to reset the filename file. The Log file will not be available with correct entries
2038: Unable to log status in the filename file. The Log file will not be available with correct entries
2040: An internal error error_code occurred while getting the server details. The Inventory scan will terminate unsuccessfully
2041: An internal error error_code occurred while attaching NLM to the file server. The Inventory scan will terminate unsuccessfully
2042: An internal error error_code occurred in LoginObject( ). The Inventory scan results might not be accurate
2043: An internal error error_code occurred in getting the NDS Tree name. The Inventory scan results might not be accurate
2044: An error error_code occurred while initializing internal Classes. The Inventory scan will terminate unsuccessfully
2045: An error error_code occurred while initializing the internal custom dictionary. The Inventory scan will terminate unsuccessfully
2046: An error error_code occurred while loading the custom dictionary. The software inventory scan results might not be accurate
2047: An error error_code occurred while initializing internal rules. The Inventory scan will terminate unsuccessfully
2048: An error error_code occurred while loading rules. The software inventory scan results might not be accurate
2051: An internal error occurred in memory allocation when a single processor was online. The Inventory scan will terminate unsuccessfully
2052: An internal error error_code occurred in fSWScanInit( ). The Inventory scan will terminate unsuccessfully
2053: An internal error occurred in memory allocation when processor(s) were online. The Inventory scan will terminate unsuccessfully
2054:An internal error error_code occurred in fSWScanInitWork( ). The Inventory scan will terminate unsuccessfully
2055: An internal error error_code occurred in fSWScanStartWork( ). The Inventory scan will terminate unsuccessfully
2056: An internal error error_code occurred in the software scan
2057: An error error_code occurred in procuring the number of installed products. The software inventory scan results will not be available
2058: An error error_code occurred while generating the internal Software report. The software inventory scan results will not be available
2059: An error error_code occurred in initializing Thread. The software inventory scan results might not be accurate
2060: An error error_code occurred in initializing WorkToDo message. The software inventory scan results might not be accurate
2061: An error error_code occurred while scheduling WorkToDo message. The software inventory scan results might not be accurate
2062: error_code volume is inactive. The software inventory for this volume will not be available
2063: Did not scan any installed products. Software inventory will not be available
2063: Did not scan any installed products. Software inventory will not be available
2065: Unable to locate the _DMI structures. System Management (SMBIOS) hardware inventory will not be available
2066: The _DMI structures do not checksum to 00h. System Management (SMBIOS) hardware inventory will not be available
2067: The _SM_ Structure Entry Point structure does not checksum to 00h. System Management (SMBIOS) hardware inventory scan results might not be accurate
2068: Unable to read the DMI BIOS structures. System Management (SMBIOS) hardware inventory will not be available
2069: Unable to open the inventory information file filename. Error code = error_code. System Management (SMBIOS) hardware inventory will not be available
093: Inventory Scanning is disabled