An error occurred while retrieving the view. The view might contain OIDs of MIBs that are not present in the MIB Pool
Source:
ZENworks 7 Server Management; Management and Monitoring Services; View Builder
Severity:
Important
Possible Cause:
You have created the View using OIDs of different MIB modules, deleted these MIB modules from the MIB Pool, and recompiled the MIBs.
Action:
Add the MIBs to the MIB Pool and recompile the MIBs.
An error occurred while retrieving the view. The view does not exist
Source:
ZENworks 7 Server Management; Management and Monitoring Services; View Builder
Severity:
Important
Possible Cause:
The view you are trying to access was deleted by another user from a different machine.
An error occurred while retrieving the view
Source:
ZENworks 7 Server Management; Management and Monitoring Services; View Builder
Severity:
Important
Possible Cause:
A general error has occurred on the server . Try again.
The No Such Name error has occurred in the view component: 0 for the MIB Variable 1
Source:
ZENworks 7 Server Management; Management and Monitoring Services; View Builder
Severity:
Important
Possible Cause:
The OID you are trying to obtain from the agent is not implemented.
Action:
Load the agent that has implemented the OID if it is not already loaded.
The proxy server is not responding. Try again
Source:
ZENworks 7 Server Management; Management and Monitoring Services; View Builder
Severity:
Important
Possible Cause:
There is a problem with the connection with the site server. Check the connection and try again.
The graph {0} of the view component {1} is not trended on this agent
Source:
ZENworks 7 Server Management; Management and Monitoring Services; View Builder
Severity:
Important
Possible Cause:
The OID of the graph is not trended by the Advanced Trending Agent.
The SNMP agent on this node is not responding
Source:
ZENworks 7 Server Management; Management and Monitoring Services; View Builder
Severity:
Important
Possible Cause:
The time-out period you have specified for this agent is too short.
Action:
Specify a higher value as the time-out period:
-
Right-click the node and select .
-
Click the tab > .
-
In the pane, select the from the drop-down list.
-
Specify an appropriate time-out period.
Possible Cause:
The SNMP Agent is not loaded on the node.
Action:
Load the SNMP agent on the node.
The view you are editing does not exist
Source:
ZENworks 7 Server Management; Management and Monitoring Services; View Builder
Severity:
Important
Possible Cause:
The view you are trying to edit was deleted by a different user from a different machine.
The view you are deleting does not exist
Source:
ZENworks 7 Server Management; Management and Monitoring Services; View Builder
Severity:
Important
Possible Cause:
The view you are trying to edit was deleted by a different user from a different machine.
An error occurred while retrieving a view
Source:
ZENworks 7 Server Management; Management and Monitoring Services; View Builder
Severity:
Important
Explanation:
This error occurs when you try to open the View Builder after upgrading from ZENworks for Servers 3.0.2 to ZENworks 7 Server Management.
Possible Cause:
When you upgraded the Management Site Server from ZENworks for Server 3.0.2 to ZENworks 7 Server Management, the MIB database was not updated. Because the ZENworks 7 Server Management View Builder depends on new definition of the MIB database, the View Builder fails in retrieving the view.
Action: