14.0 DSDIAGNOSTICS Messages

The following messages include messages from the DSDIAG.NLM.

DSDiag-x-001: Process data not found. Exiting process.

Source: DSDIAG.NLM
Explanation: The report process could not locate its data to initialize the report.
Possible Cause: This is an unexpected error.
Action: Unload DSDIAGNOSTICS and then reload it. If the error persists, contact a Novell® support provider.

DSDiag-x-002: Insufficient memory error.

Source: DSDIAG.NLM
Possible Cause: This server does not have enough memory to create a report.
Action: Exit all of the reports that are running except for the current report. Let the current report run to completion and try again.
Action: Increase memory available to the server. See Freeing Server Memory Temporarily in the NW 6.5 SP8: Server Operating SystemAdministration Guide.

DSDiag-x-003: Could not create initial context.

Source: DSDIAG.NLM
Explanation: An error occurred in the load process. This is an unexpected error.
Action: Check for possible configuration errors and reboot. If this error occurs repeatedly, contact a Novell support provider.

DSDiag-x-004: This NLM requires a newer version of NWSNUT.

Source: DSDIAG.NLM
Explanation: While loading, DSDIAG.NLM determined that the version of nwsnut.nlm does not support the functionality required by DSDIAG.NLM.
Action: Update the version of nwsnut.nlm on the server.

DSDiag-x-005: This NLM was unable to initialize NWSNUT.

Source: DSDIAG.NLM
Explanation: NWSNUT, the support NLM program, returned an error from the initialization process.
Possible Cause: An internal error occurred.
Action: Try the operation again. If the error persists, contact a Novell support provider.

DSDiag-x-006: Unable to register for volume dismount event.

Source: DSDIAG.NLM
Explanation: An error occurred while DSDIAGNOSTICS was trying to register for operating sytem resources.
Action: Try running DSDIAGNOSTICS again, or reboot the server.

DSDiag-x-007: Unable to allocate memory for process stack.

Source: DSDIAG.NLM
Explanation: This server does not have enough available memory.
Action: Increase memory available to the server. See Freeing Server Memory Temporarily in the NW 6.5 SP8: Server Operating SystemAdministration Guide.

DSDiag-x-008: Unable to open screen.

Source: DSDIAG.NLM
Explanation: An error occurred while DSDIAGNOSTICS was trying to register for operating system resources.
Action: Try running DSDIAGNOSTICS again, or reboot the server.

DSDiag-x-009: Error writing to log file, log file closed.

Source: DSDIAG.NLM
Explanation: The volume the log file is writing to is unmounted or the removable media (for example, floppy, CD, or cartridge) is unavailable.
Action: Mount the volume or make sure the removable media is working properly.

DSDiag-x-010: Could not register with the Tool Manager.

Source: DSDIAG.NLM
Explanation: DSDIAGNOSTICS processes data and tracks resources used by each of the reports and should always be available. This is an unexpected error.
Action: Exit the report, unload DSDIAGNOSTICS and then reload it.

DSDiag-x-011: Maximum NWSNUT portals reached.

Source: DSDIAG.NLM
Explanation: The maximum number of NWSNUT portals is set by the NUT NLM™ and is version dependent. In this case, that maximum has been reached.
Action: Unload DSDIAGNOTICS reboot the server, and then reload DSDIAGNOSTICS.

DSDiag-x-012: Unknown command line switch.

Source: DSDIAG.NLM
Explanation: An unknown command line switch was used.
Action: Use only supported switches. For a list of supported switches enter /?.

DSDiag-x-013: USAGE: No switches.

Source: DSDIAG.NLM
Explanation: No switches are supported in this version of DSDIAGNOSTICS.
Action: Do not use command line switches in this version displayed in the message.