14.0 DSDIAGNOSTICS Messages
The following messages include messages from the DSDIAG.NLM.
DSDiag-x-001: Process data not found. Exiting process.
Source:
DSDIAG.NLM
Explanation:
The report process could not locate its data to initialize the report.
Possible Cause:
This is an unexpected error.
Action:
Unload DSDIAGNOSTICS and then reload it. If the error persists, contact a Novell® support provider.
DSDiag-x-002: Insufficient memory error.
Source:
DSDIAG.NLM
Possible Cause:
This server does not have enough memory to create a report.
Action:
Exit all of the reports that are running except for the current report. Let the current report run to completion and try again.
DSDiag-x-003: Could not create initial context.
Source:
DSDIAG.NLM
Explanation:
An error occurred in the load process. This is an unexpected error.
Action:
Check for possible configuration errors and reboot. If this error occurs repeatedly, contact a Novell support provider.
DSDiag-x-004: This NLM requires a newer version of NWSNUT.
Source:
DSDIAG.NLM
Explanation:
While loading, DSDIAG.NLM determined that the version of nwsnut.nlm does not support the functionality required by DSDIAG.NLM.
Action:
Update the version of nwsnut.nlm on the server.
DSDiag-x-005: This NLM was unable to initialize NWSNUT.
Source:
DSDIAG.NLM
Explanation:
NWSNUT, the support NLM program, returned an error from the initialization process.
Possible Cause:
An internal error occurred.
Action:
Try the operation again. If the error persists, contact a Novell support provider.
DSDiag-x-006: Unable to register for volume dismount event.
Source:
DSDIAG.NLM
Explanation:
An error occurred while DSDIAGNOSTICS was trying to register for operating sytem resources.
Action:
Try running DSDIAGNOSTICS again, or reboot the server.
DSDiag-x-007: Unable to allocate memory for process stack.
Source:
DSDIAG.NLM
Explanation:
This server does not have enough available memory.
DSDiag-x-008: Unable to open screen.
Source:
DSDIAG.NLM
Explanation:
An error occurred while DSDIAGNOSTICS was trying to register for operating system resources.
Action:
Try running DSDIAGNOSTICS again, or reboot the server.
DSDiag-x-009: Error writing to log file, log file closed.
Source:
DSDIAG.NLM
Explanation:
The volume the log file is writing to is unmounted or the removable media (for example, floppy, CD, or cartridge) is unavailable.
Action:
Mount the volume or make sure the removable media is working properly.
DSDiag-x-010: Could not register with the Tool Manager.
Source:
DSDIAG.NLM
Explanation:
DSDIAGNOSTICS processes data and tracks resources used by each of the reports and should always be available. This is an unexpected error.
Action:
Exit the report, unload DSDIAGNOSTICS and then reload it.
DSDiag-x-011: Maximum NWSNUT portals reached.
Source:
DSDIAG.NLM
Explanation:
The maximum number of NWSNUT portals is set by the NUT NLM™ and is version dependent. In this case, that maximum has been reached.
Action:
Unload DSDIAGNOTICS reboot the server, and then reload DSDIAGNOSTICS.
DSDiag-x-012: Unknown command line switch.
Source:
DSDIAG.NLM
Explanation:
An unknown command line switch was used.
Action:
Use only supported switches. For a list of supported switches enter /?.
DSDiag-x-013: USAGE: No switches.
Source:
DSDIAG.NLM
Explanation:
No switches are supported in this version of DSDIAGNOSTICS.
Action:
Do not use command line switches in this version displayed in the message.