When you upgrade a Primary Server to ZENworks 11 SP3 for the first time in the Management Zone, complete the following tasks before running the upgrade:
Ensure that the Primary Server that you want to upgrade to ZENworks 11 SP3 meets all the ZENworks 11 SP3 system requirements.
For more information, see Primary Server Requirements
in the ZENworks 11 SP3 Server Installation Guide.
Back up the ZENworks database.
The time required to complete the upgrade on the first Primary Server depends on the size of the data present in database. If the first Primary Server upgrade is on a device that is using an MS SQL or Oracle database, then run the upgrade in a test environment (with server data similar to the production environment). This is to calculate the outage time of the production server.
Ensure that there is no high CPU utilization or memory utilization during the first Primary Server upgrade.
Stop all ZENworks services on any Primary Server that is not being upgraded in order to prevent the database from being accessed during the upgrade. Otherwise, this might result in the database going into a nonrecoverable state.
For information about stopping ZENworks services:
On a Windows Primary Server:
See ZENworks Services on a Windows Server
in the ZENworks 11 SP3 Primary Server and Satellite Reference.
On a Linux Primary Server:
See ZENworks Services on a Linux Server
in the ZENworks 11 SP3 Primary Server and Satellite Reference.
When you upgrade the first server, then the System Update is available to upgrade the ZENworks Satellite Servers and managed devices to ZENworks 11 SP3.
Ensure that the server hosting the database is running with an active database.
On a Linux Primary Server, ensure that the c3p0,the hibernate logs for ZENLoader, and ZENServer are disabled prior to the upgrade. For more information, see TID 7015032.
Ensure that the time on the server and the database are synchronized (time difference must be less than 2 minutes).
NOTE:
If the time difference is more than 2 minutes and less than 24 hours, a warning message is displayed during the upgrade.
If the time difference is more than 24 hours, an error message is displayed.
Ensure that the Windows Primary Servers have Windows Installer 4.5 or later versions installed and running.
(Recommendation) For the server upgrade, an OEM ZENworks database and an Audit database cannot be present on the same device; the databases must be hosted on different devices.
Ensure that all fixed ports are free during the upgrade. If the fixed ports are blocked, the upgrade fails. For the list of ports, see TCP and UDP Ports Used by ZENworks Primary Servers
in ZENworks 11 SP3 Primary Server and Satellite Reference.
If you have obtained the ZENworks upgrade software as an ISO image download, do one of the following to create the upgrade DVD:
IMPORTANT:Do not extract and use the ISO image for upgrading to ZENworks 11 SP3.
Download the ZENworks 11 SP3 upgrade ISO image from the Novell Download website to a temporary location on your Windows device.
Burn the ISO image to a DVD.
Download the ZENworks 11 SP3 upgrade ISO image from the Novell Download website to a temporary location on your Linux device.
Mount the ISO image by using the following command:
mount -o loop /tempfolderpath/isoimagename.iso mountpoint
Replace tempfolderpath with the path of the temporary folder, replace isoimagename with the ZENworks ISO file name, and replace mountpoint with the path of the file system location where you want to mount the image. The path specified by mountpoint must already exist.
For example:
mount -o loop /zcm11/ZCM11upgr.iso /zcm11/upgrade