The information in this Readme pertains to the ZENworks 2017 Update 2 release.
The following table contains information on the documentation content changes that were made in this Readme after the initial release of ZENworks 2017 Update 1:
Table 1 Readme Updates
Date |
Readme Item Added or Updated |
---|---|
June, 2019 |
A new item has been included in the following section: Section 2.0, Important The following known issue has been added: Section 8.13, Upgrade of a ZENworks 17.x appliance to a later version fails if the April 2019 Appliance Security Patches have been applied |
Prior to installing the update, please read the following information:
If you have downloaded ZENworks 2017 Update 2 but not deployed it in your zone as yet, ensure that you DO NOT deploy it. Please DELETE ZENworks 2017 Update 2 and only deploy ZENworks 2017 Update 2a to avoid the issue documented in TID 7022612.
If you have already deployed or are in the process of deploying ZENworks 2017 Update 2, you need to contact customer support or refer to TID 7022612. After taking the required action, you can continue with the deployment of ZENworks 2017 Update 2 and ignore ZENworks 2017 Update 2a.
If you have applied the April 2019 Appliance Security Patches, before upgrading to ZENworks 2017 Update 2a, you need to first apply the FTF that is available in bug 1134324.
For information on the new features included in this release, see What’s New in ZENworks 2017 Update 2.
Use the following guidelines to plan for the deployment of ZENworks 2017 Update 2 in your Management Zone:
If you are using Disk Encryption and you want to update the Full Disk Encryption Agent from a version earlier than ZENworks 2017 Update 1, you MUST remove the Disk Encryption policy from those managed devices before you update them to ZENworks 2017 Update 2.
If you are updating the Full Disk Encryption Agent from ZENworks 2017 Update 1 to Update 2, leave the Disk Encryption policy in place, no change is required prior to the system update.
For more information about updating Full Disk Encryption in ZENworks 2017 Update 2 from a version earlier than ZENworks 2017 Update 1, see the ZENworks 2017 Update 2 - Full Disk Encryption Update Reference.
You must first upgrade the Primary Servers, then update the Satellite Servers, and finally the managed devices to ZENworks 2017 Update 2. Do not upgrade the managed devices and Satellite Servers (or add new 2017 Update 2 Agents in the zone) until all Primary Servers in the zone have been upgraded to ZENworks 2017 Update 2.
NOTE:Agents might receive inconsistent data from the zone until all Primary Servers are upgraded. Therefore, this part of the process should take place in as short a time as possible - ideally, immediately after the first Primary Server is upgraded.
You can directly deploy version 2017 Update 2 to the following devices:
Device Type |
Operating System |
Minimum ZENworks Version |
---|---|---|
Primary Servers |
Windows and Linux |
ZENworks 2017 and subsequent versions |
Satellite Servers |
Windows, Linux and Mac |
ZENworks 11.x and subsequent versions |
Managed Devices |
Windows |
ZENworks 11.x and subsequent versions |
Linux |
ZENworks 11.x and subsequent versions |
|
Mac |
ZENworks 11.2 and subsequent versions |
The system reboots once after you upgrade to ZENworks 2017 Update 2. However, a double reboot will be required in the following scenarios:
If you update from 11.x to ZENworks 2017 or 2017 Update 2 with Endpoint Security enabled, you will need a second reboot to load the ZESNETAccess driver.
If a managed device uses Windows 10 with Client Self Defense enabled and you are upgrading from 11.4.x to ZENworks 2017, 2017 Update 1 or 2017 Update 2, you need to disable Client Self Defense in ZENworks Control Center, reboot the managed device, and then run the update, requiring a second reboot on the device.
If you have a Disk Encryption policy enforced on a managed device, and you want to update the Full Disk Encryption Agent from a version earlier than ZENworks 2017 Update 1 to ZENworks 2017 Update 2, you must first remove the policy and decrypt the device, which requires a device reboot. You then update the device to 2017 Update 2, requiring a second reboot.
IMPORTANT:Managed Devices running versions prior to 11.x must first be upgraded to 11.x. The system reboots after the upgrade to 11.x and then reboots again when the ZENworks 2017 Update 2 system update is deployed.
Prior to installing the System Update, ensure that you have adequate free disk space in the following locations:
Location |
Description |
Disk Space |
---|---|---|
Windows: %zenworks_home%\install\downloads Linux: opt/novell/zenworks/install/downloads |
To maintain agent packages. |
5.5 GB |
Windows: %zenworks_home%\work\content-repo Linux: /var/opt/novell/zenworks/content-repo |
To import the zip file to the content system. |
5.5 GB |
Agent Cache |
To download the applicable System Update contents that are required to update the ZENworks server. |
1.5 GB |
Location where the System Update file is copied. This is only applicable for the ZENworks Server that is used to import the System Update zip file |
To store the downloaded System Update zip file. |
5.5 GB |
For instructions on downloading and deploying ZENworks 2017 Update 2, see the ZENworks System Updates Reference.
If your Management Zone consists of Primary Servers with a version prior to ZENworks 2017, you can deploy ZENworks 2017 Update 2 to these Primary Servers only after all of them have been upgraded to ZENworks 2017. For instructions, see the ZENworks Upgrade Guide.
For administrative tasks, see the ZENworks 2017 Update 2 documentation site.
IMPORTANT:Do not update the Remote Management (RM) viewer until all the Join Proxy Satellite Servers are updated in the zone. To perform Remote Management through Join Proxy, you need to ensure that the RM viewer version and the Join Proxy version are the same.
Ensure that you read Section 4.0, Planning to Deploy ZENworks 2017 Update 2 before you download and deploy the ZENworks 2017 Update 2 update.
This update requires schema changes to be made to the database. During the initial patch installation, the services will run only on the Master or dedicated Primary Server. This is to ensure that other Primary Servers do not try to access the tables being changed in the database.
After the Master or dedicated Primary Server has been updated, the services will resume on the remaining servers and the update will be applied simultaneously.
NOTE:You do not need to manually stop or start the services on the servers during the update. The services will be stopped and started automatically.
When you postpone a system update and log out of the managed device, the system update is applied on the device.
For the list of supported Managed Device and Satellite Server versions in a Management Zone with ZENworks 2017 Update 2, see Supported Managed Devices and Satellite Server Versions.
Some of the issues identified in previous releases have been addressed in this release. For a list of the resolved issues, see TID 7022513 in the Support Knowledgebase.
Some of the issues that were discovered in versions prior to ZENworks 2017 Update 2 and have not yet been resolved. Review the following Readme documents for more information:
This section contains information about issues that might occur while you work with ZENworks 2017 Update 2:
When the Gmail app is remotely configured on a device enrolled in the work profile mode, using the managed configurations feature, the following issues might occur:
The app cannot be hidden if the device becomes non-compliant
Changes made to the managed configuration of the Gmail app are not effective on an enrolled device
The app does not uninstall automatically when the associated bundle is unassigned
Workaround: None. This is a Google limitation.
ZENworks does not reclaim an app license automatically if the associated bundle is unassigned from either of the following:
A device that does not sync with the ZENworks Server
A user, and one of the devices associated with the user does not sync with the server. In this case, the license is not reclaimed until all the devices associated with this user sync with the ZENworks Server
Workaround: To reclaim the license, unenroll the device from ZENworks.
As a part of the system update deployment process, even though you uncheck the Reboot device when the device is locked option, Windows 10 devices that are locked, might get rebooted after the system update is completed. This issue is related to the Windows 10 native APIs (OpenInputDesktop /SwitchDesktop), which return random values when the device is locked.
Workaround: None
Microsoft has deprecated SNMP, so when you perform SNMP discovery from ZENworks, it might detect the latest Windows operating system as Windows 8.1 even if it is a later version.
Workaround: None
When you restore the image of a Windows device with Windows 10 updates, using the Legacy NTFS driver, the restored device might not boot the operating system.
Workaround: Perform any one of the following:
Take and restore an image of the device using the Tuxera driver.
Take and restore an image of the device in the .zmg format using WinPE.
When you update a Scientific Linux 7.x device with ZENworks 2017 Update 2, the prerequisite check fails.
Workaround: Disable the Remote Management Spoke, and then deploy the update.
When secure boot is enabled on the device, and you select the Windows boot manager option from the ZEN partition menu to boot the operating system, the following error message is displayed: ZENworks is unable to load Windows through ZENPartition. You need to either disable Secure Boot or select Windows Boot Manager from the Boot Menu.
Workaround: Perform any of the following:
Reboot the device and select Windows boot manager from the boot menu
Disable secure boot
When a proxy is used to send the Wake on LAN quick task to a managed device, the Quick Task Status dialog box displays a failed message even if the quick task has succeeded.
Workaround: None
When you run the full inventory scan on a Windows 10 device, during software collection, the following exception is included in the ZMD message log:
The specified path, file name, or both are too long. The fully qualified file name must be less than 260 characters, and the directory name must be less than 248 characters.
Workaround: In the Windows 10 Local Group Policy Editor, enable the win32 long paths option.
To enable the win32 long paths option on a managed device:
Click the Start Menu and enter gpedit.msc in the search field.
In the Local Group Policy Editor window, go to Computer Configuration > Administrative Templates > System > Filesystem
In the right pane, double-click Enable win32 long paths.
In the Enable win32 long paths window, select Enabled and then click OK.
Restart the device.
NOTE:To Enable win32 long paths on all managed devices in the zone, in ZCC, create a Windows Group Policy to enable win32longpaths and assign it to all the managed devices in the zone.
For more information, see the Windows Group Policy section in the ZENworks Configuration Policies Reference.
If you edit a domain that is configured with the Microsoft SQL server database and a resource file, the specify a valid port message is displayed even though the Instance name is specified.
Workaround: Delete the Instance name and re-enter the Instance name.
On Windows 10 managed devices with the Fall Creators Update (Build 1709), you will not be logged in passively after performing a reboot or shutdown and restart of the device because the Winlogon Automatic Restart Sign-On (ARSO) is set as Default for user startup.
Workaround: Disable ARSO using a registry or a group policy. If you are not using a policy, a registry bundle can be created to set the registry before assigning it to devices. For more information, see TID 7022379 in the Support Knowledge Base.
After upgrading Windows 10 to version 1709 from an earlier version, the user turns off the device using the Power button. When the device is powered on again, it blue screens.This scenario only occurs when Windows 10 cumulative updates are not kept current in Windows 10 versions 1607 and 1703 prior to upgrading to Windows 10 v1709, and only on devices using Disk Encryption. A power down using the Windows menu does not produce this issue.
Workaround: Ensure Windows 10 devices that use Full Disk Encryption are fully patched with Windows updates prior to upgrading to Windows 10 version 1709.
If you have applied the April 2019 Appliance Security Patches and then you try to upgrade a ZENworks 17.x appliance to a later version, some of the symbolic links (symlinks) such as /opt/novell/zenworks/lib32 and /opt/novell/zenworks/lib64 are replaced by new folders and hence the update fails.
Workaround: Apply the FTF that is available in bug 1134324 and then run the update again.
This Readme lists the issues specific to ZENworks 2017 Update 2 release. For all other ZENworks 2017 documentation, see the ZENworks 2017 documentation website.
For information about legal notices, trademarks, disclaimers, warranties, export and other use restrictions, U.S. Government rights, patent policy, and FIPS compliance, see https://www.novell.com/company/legal/.
Copyright © 2018 Micro Focus Software Inc. All Rights Reserved.