6.5 C04x Errors

C040 Database error

Source: GroupWise engine; database services.

C042 Database being modified

Source: GroupWise engine; database services.
Explanation: Read consistent view of record not available.
Possible Cause: A read operation encountered data that was being modified by another concurrent program. The read operation needs to see a prior version of the data; however, no prior version is available. This error should be handled by the GroupWise engine in most cases. If it finally does come through to the end user, it might indicate there is a problem with the database. However, it might also indicate the update activity on the database is currently very high.
Action: Generally, the error is transitory and goes away when the operation is retried. Make sure that others are not doing updates to the database, and retry the action. If the problem persists, validate and rebuild the database as necessary. See Maintaining Domain and Post Office Databases and Maintaining User/Resource and Message Databases in Databases in the GroupWise 8 Administration Guide.
Action: If this error occurs on a message or user database, run GWCheck. See Standalone Database Maintenance Programs in the GroupWise 8 Administration Guide.

C043 Database error

Source: GroupWise engine; database services.

C044 Database error

Source: GroupWise engine; database services.

C045 Unexpected error

Source: GroupWise engine; database services.
Action: See C0xx Unexpected error.

C046 Database error

Source: GroupWise engine; database services.

C047 Database error

Source: GroupWise engine; database services.

C048 Unexpected error

Source: GroupWise engine; database services.
Action: See C0xx Unexpected error.

C04A Unexpected error

Source: GroupWise engine; database services.
Action: See C0xx Unexpected error.

C04B Database error

Source: GroupWise engine; database services.

C04C Database error

Source: GroupWise engine; database services.

C04D Memory error

Source: GroupWise engine; database services.
Action: See C0xx Memory error.

C04E Database error

Source: GroupWise engine; database services.

C04F Database checksum error

Source: GroupWise engine; database services.
Explanation: Checksum error reading database.
Action: Check and, if necessary, repair the database. See Maintaining Domain and Post Office Databases and Maintaining User/Resource and Message Databases in Databases in the GroupWise 8 Administration Guide.

If the error returns, check for bad network cards on workstations from which the GroupWise client updates the databases.

Action: If this error occurs on a message database (msgnnn.db) or user database (userxxx.db), run GWCheck. See Standalone Database Maintenance Programs in Databases in the GroupWise 8 Administration Guide.
Possible Cause: The guardian database (ngwguard.db) is damaged.
Action: Stop the POA. Make backup copies of the ngwguard.db, ngwguard.rfl, and ngwguard.fbk files. Delete the ngwguard.db file, then create a new, empty file named ngwguard.db.

Start the POA. The POA will recognize the invalid ngwguard.db file and rebuild it from the ngwguard.fbk file, merging in transactions from the ngwguard.rfl file.

See also Information Stored in the Post Office in Post Office Agent in the GroupWise 8 Administration Guide.

Possible Cause: If this error occurs in the GroupWise client in Remote mode, there might be a problem with the structure or content of the Remote mailbox.
Action: Delete the rofdata directory on the remote computer, then request all information from the master mailbox again.
Action: Reinstall GroupWise on the remote computer. See the platform-specific setup instructions for using Remote mode in Setting Up GroupWise Modes and Accounts in Client in the GroupWise 8 Administration Guide.
Possible Cause: If this error occurs in the GroupWise client in the Find Results dialog box, the POA has not indexed the documents yet and might not be running.
Action: Start the POA. Check its indexing cycle. See Regulating Indexing in Optimizing the POA in the GroupWise 8 Administration Guide.

After the documents have been indexed, the user will be able to use the Find feature in the GroupWise client to access them.